Installation instructions, Preparing the opening – GE PGP966DETBB Manuel d'utilisation
Page 4
Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

Installation Instructions
PREPARING THE OPENING
[Ü MAINTAIN THE FOLLOWING
MINIMUM CLEARANCE DIMENSIONS
13" MAX. Depth of unprotected
overhead cabinets
30" MIN. clearance from countertop
to unprotected overhead surface
3-3/4" MIN. clearance from
cutout to side wall on the
left of the unit
fj" MIN. clearance from
cutout to side wall on the
/ right of the unit
18" MIN. height
from countertop to
nearest cabinet on
either side of unit
NOTE: Allow 7/15"
minimum vertical
clearance from the
cooktop bottom (or
3-5/8" minimum depth
from the countertop)
to any combustible
surfaces, such as a
cabinet drawer.
For island installation,
maintain 2-1/2 in.
minimum from cutout to front and back edge of
countertop. Maintain 3 in. minimum from cutout to
side edges of countertop.
H OVERALL COOKTOP DIMENSIONS
18-7/8"
33-11/16"
21" (21-1/4" Max. for
Glass Top models)
\
3-3/16"
I f (3-l/16"on
ModelZGU36)
H CUTOUT DIMENSIONS OF
COUNTERTOP
To ensure accuracy, it is best to make a template
when cutting the opening in the counter.
19-1/8" width cut
33-7/8" ^
----
length^^
16-15/16"
of cut
^
' '
2-1/4" Min. Between
cutout and the wall
behind the cooktop
2-1/2" Min. from
front edge of cutout
and front edge of
countertop
H RECOMMENDED GAS SUPPLY
LOCATION FROM BACKWALL
1" Min. From Backwall
t
Recommended
gas supply
location
From Cutout
Center Line
H MAKE SURE WALL COVERINGS,
COUNTERTOP AND CABINETS
AROUND COOKTOP CAN
WITHSTAND HEAT (UP TO 200“F)
GENERATED BY COOKTOP
Wall covering,
cabinets and
countertop must
withstand heat
up to 200°F
H FOR AMERICANS WITH DISABILITIES
ACT (ADA) FORWARD APPROACH
INSTALLATION ONLY:
-5”-,
Allow 5" minimum
depth between the
countertop and on
enclosure.
NOTE: The enclosure must be mode of wood
material. Also, on access panel is reguired for the
electrical outlet, pressure regulator, shut-off valve,