Cooktop requirements, Base cabinet requirements, Power supply – GE ZGU384NSMSS Manuel d'utilisation
Page 12: Installation options
Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

Installation Options
COOKTOP INSTALLATION WITH A
30" MONOGRAM DOWNDRAFT VENT,
MODEL ZVB30
The installation of the downdraft vent with
this cooktop requires careful consideration.
Both the cooktop and the vent must be installed
according to each specific installation instruction.
COOKTOP REQUIREMENTS
The countertop must have a deep flat surface to
accommodate the cooktop and vent. Countertops
with a rolled front edge and backsplash will not
provide the flat surface area required.
• Review the illustration to determine the countertop
surface requirements.
- All cutout clearances for this installation must be
observed.
----------30-3/4"--------
28-1/2" vent cutout
2-3/4"
22-3/8"
cutout
depth
19-5/8"
cooktop
cutout
depth
-------- ^-------
28-1/2" cooktop area
— cutout —
7/16" cooktop overlap
(1-1/4" at center)
-t-
^
Front edge of countertop
BASE CABINET REQUIREMENTS
The combined installation will fit in a standard
24" deep base cabinet. Use a 30" or wider base
cabinet.
- The vent housing, blower and ductwork will
occupy the base cabinet.
1
/
8
"
gap
2-7/8" min. cooktop
cutout to rear vertical
combustible surface
23-7/8"
total flat
surface
required
at center
2-1/2" min. clearance to
cutout
POWER SUPPLY
12" min. cutout to
wall, both sides
If local codes permit, the vent and cooktop may
operate from the same 120V, 15 amp duplex outlet.
Locate the gas and electrical supply as shown on
page 8.
12