Spécifications cobalt de “base, Non homologué) et homologué – AXEON Cobalt-Series Manuel d'utilisation

Page 21

Advertising
background image

Specifications Cobalt “BASIC” (non-certified) and Certified:

MODEL

SC-200/SCV-200

*

SC-320/SCV-320

*

SC-600/SCV-600

*

SC-740/SCV-740

*

Flo

w Rat

e

NSF 55 Class B
16mJ/cm

2

@ 70% UVT

*

16.7 lpm

(4.4 gpm)

(1.0 m

3

/hr)

26.1 lpm

(6.9 gpm)

(1.6 m

3

/hr)

42.2 lpm

(11.1 gpm)

(2.5 m

3

/hr)

59.8 lpm

(15.8 gpm)

(3.6 m

3

/hr)

US Public Health
16 mJ/cm

2

@ 95% UVT

56.8 lpm

(15 gpm)

(3.4 m

3

/hr)

94.6 lpm

(25 gpm)

(5.7 m

3

/hr)

227.1 lpm

(60 gpm)

(13.6 m

3

/hr)

227.1 lpm

(60 gpm)

(13.6 m

3

/hr)

VIQUA Standard
30 mJ/cm

2

@ 95% UVT

30.3 lpm

(8 gpm)

(1.8 m

3

/hr)

49.2 lpm

(13 gpm)

(3.0 m

3

/hr)

121.1 lpm

(32 gpm)

(7.3 m

3

/hr)

151.4 lpm

(40 gpm)

(9.1 m

3

/hr)

NSF/EPA
40mJ/cm

2

@ 95% UVT

22.7 lpm

(6 gpm)

(1.4 m

3

/hr)

37.8 lpm

(10 gpm)

(2.3 m

3

/hr)

90.8 lpm

(24 gpm)

(5.5 m

3

/hr)

113.6 lpm

(30 gpm)

(6.8 m

3

/hr)

Dimensions

Reactor

45.2 x 8.9 cm

(17.8“ x 3.5“)

57.9 x 8.9 cm

(22.8“ x 3.5“)

78 x 8.9 cm

(30.7“ x 3.5“)

100 x 6.4 cm

(39.7“ x 2.5“)

Controller

24.1 cm x 8.1 cm x 6.4 cm

(9.4“ x 3.2“ x 2.5“)

Inlet/Outlet Port Size

Combo

3/4“ FNPT/

1“ MNPT

Combo 3/4FNPT/

1“ MNPT

1“ MNPT

1.5“ MNPT

Shipping Weight

5.4 kg

(12 lbs)

6.8 kg

(15 lbs)

8.6 kg

(19 lbs)

10.9 kg

(24 lbs)

Electr

ical

Voltage

100-240V/

50-60Hz

100-240V/

50-60Hz

100-240V/

50-60Hz

100-240V/

50-60Hz

Power
Consumption

35 W

42 W

70 W

82 W

Lamp Watts

27 W

34 W

58 W

70 W

Maximum
Operating Pressure

8.62 bar

(125 psi)

8.62 bar

(125 psi)

8.62 bar

(125 psi)

8.62 bar

(125 psi)

Ambient Water
Temperature

2-40˚C

(36-104˚F)

2-40˚C

(36-104˚F)

2-40˚C

(36-104˚F)

2-40˚C

(36-104˚F)

Lamp Type

Sterilume™-HO (high-output)

Visual
“Power-On”

Yes

Yes

Yes

Yes

Audible Lamp Failure

Yes

Yes

Yes

Yes

Lamp
Replacement
Reminder

Yes

Yes

Yes

Yes

Visual Lamp Life
Remaining

Yes

Yes

Yes

Yes

Total Running Time

Yes

Yes

Yes

Yes

Chamber Material

304 SS

304 SS

304 SS

304 SS

Fl

ow

R

es

tr

ic

to

r

Size

1” MNPT

1” MNPT

1” MNPT

1.5” MNPT

Length

(2.75”)

7 cm

(2.75”)

7 cm

(2.75”)

7 cm

(2.75”)

7 cm

17

Spécifications Cobalt de “base

(non homologué) et homologué :

17

MODÈLE

SC-

200

/SC

V -2

00

*

SC

-32

0/S

CV-

320

*

SC-

600

/SC

V -6

00

*

SC

-74

0/S

CV

-74

0

*

Débit

NSF 55 Classe B

16 MJ/cm

2

à un TUV de 70 %

*

16,7 lpm

(4,4 gpm)

(1,0 m

3

/h)

26,1 lpm

(6,9 gpm)

(1,6 m

3

/h)

42,2 lpm

(11,1 gpm)

(2,5 m

3

/h)

59,8 lpm

(15,8 gpm)

(3,6 m

3

/h)

Santé publique

USA

16mJ/cm

2

1

à un TUV de 95 %

56,8 lpm

(15 gpm)

(3,4 m

3

/h)

94,6 lpm

(25 gpm)

(5,7 m

3

/h)

227 ,1 lpm

(60 gpm)

(13,6 m

3

/h)

227 ,1 lpm

(60 gpm)

(13,6 m

3

/h)

Standard

VIQUA

30 MJ/cm

2

à un TUV de 95 %

30,3 lpm

(8 gpm)

(1,8 m

3

/h)

49,2 lpm

(13 gpm)

(3,0 m

3

/h)

121,1 lpm

(32 gpm)

(7 ,3 m

3

/h)

151,4 lpm

(40 gpm)

(9,1 m

3

/h)

NSF/EPA

40 MJ/cm

2

à un TUV de 95 %

22,7 lpm

(6 gpm)

(1,4 m

3

/h)

37 ,8 lpm

(10 gpm)

(2,3 m

3

/h)

90,8 lpm

(24 gpm)

(5,5 m

3

/h)

113,6 lpm

(30 gpm)

(6,8 m

3

/h)

Dimensions

Réacteur

45,

2 x

8,

9 c

m

(17

,8

po

x 3

,5

po)

57,9

x

8,9

cm

(22

,8

po

x 3

,5

po)

78

x

8,9

cm

(30

,7

po

x 3

,5

po)

100

x

6,4

cm

(39

,7

po

x 2

,5

po)

Contrôleur

24,1 cm x 8,1 cm x 6,4 cm

(9,4 po x 3,2 po x 2,5 po)

Dimension des

orifices d’entr

ée / de

sortie

Combo

3/4 po FNPT/

1 po MNPT

Combo

3/4 po FNPT/

1 po MNPT

1 po MNPT

1,5 po MNPT

Poids à l’expédition

5,4 kg

(12 lb)

6,8 kg

(15 lb)

8,6 kg

(19 lb)

10,9 k

g

(24 lb)

Électr

icit
é

T ension

100-240

V/

50-60 Hz

100-240

V/

50-60 Hz

100-240

V/

50-60 Hz

100-240

V/

50-60 Hz

Consommation

35 W

42 W

70 W

82 W

Puissance

de la lampe

27 W

34 W

58 W

70 W

Pression maximale de

service

8,62 bar

(125 psi)

8,62 bar

(125 psi)

8,62 bar

(125 psi)

8,62 bar

(125 psi)

T empér

atur

e

ambiante de l’eau

2-40 ˚C

(36-104 ˚F)

2-40 ˚C

(36-104 ˚F)

2-40 ˚C

(36-104 ˚F)

2-40 ˚C

(36-104 ˚F)

T ype de lampe

Sterilume

MC

– HO (high output) à flux éle

Affic

hage – mise sous

tension

Oui

Oui

Oui

Oui

Alarme sonor

e de

défaillance

Oui

Oui

Oui

Oui

Aver

tisseur –

remplacement de la

lampe

Oui

Oui

Oui

Oui

Affi

cha

ge

– d

uré

e

d’o

pér

ati

on

rés

idu

elle

de

la

lam

pe

Oui

Oui

Oui

Oui

Durée t

otale de

fonctionnement

Oui

Oui

Oui

Oui

Matér

iau de la chambr

e

Inox 304

Inox 304

Inox 304

Inox 304

Réducteur de débit

Dimensions

1 po MNPT

1 po MNPT

1 po MNPT

1,5 po MNPT

Longueur

(2,

75

po)

- 7

cm

(2,

75

po)

- 7

cm

(2,

75

po)

- 7

cm

(2,

75

po)

- 7

cm

Advertising