Thetford N84 Series Installation Manual - Current Manuel d'utilisation
Page 9

Installation Manual 9
Only use an upper side-wall exhaust vent on refrigerator models
that are equipped with a fan. If you use an upper side-wall exhaust
vent on a refrigerator model that is not equipped with a fan, the
refrigerator cooling performance will be poor.
- Make sure the refrigerator model is equipped with a fan.
- Install the upper side-wall exhaust vent [24] (See Art01592 and Art01593).
- For N62X, N62XXX, N64X, N64XXX, N64XIM, and N64XIMXX models, make sure the
distance [25] from the bottom of the enclosure to the top of the rough opening for the
upper exhaust vent is at least 55 inches.
- For N82X, N82XXX, N84X, N84XXX, N84XIM, and N84XIMXX models, make sure the
distance [25] from the bottom of the enclosure to the top of the rough opening for the
upper exhaust vent is at least 62 inches.
- Align the upper exhaust vent [24] horizontally above the lower intake vent [9] of the
refrigerator.
- To prevent stagnant hot air in the area above the refrigerator, install an aluminum or
galvanized steel sheet baffle [13] between the top of the refrigerator and the top of the
upper exhaust vent.
- Make sure there is less than 1/4 inch clearance between the baffle and the top of
the refrigerator and that the baffle overlaps the refrigerator 1 inch or less.
22
23
Art01601
Art01592
15 13
15
11
213
15
25
24
26
9
10
27
Art01593
27
17
10
9
18
25
21
24
15
13
15
11
15
213
CAUTION
!