Install an upper side-wall exhaust vent – Thetford 1210 Series GE - Current Manuel d'utilisation

Page 12

Advertising
background image

Installation Manual 12

If the design of the vehicle does not allow you to install a roof exhaust vent, install an upper side-wall

exhaust vent.

NOTE: The refrigerator is 23.7 in. min. to 24.0 in. max. from the rear of the breaker to the rear of the

condenser [22] and is 59.0 in. min. to 59.3 in. max. from the bottom of the refrigerator to the

bottom of the refrigerator condenser [23] (See Art01600).

CAUTION:

Only use an upper side-wall exhaust vent on refrigerator models that are equipped

with a fan. If you use an upper side-wall exhaust vent on a refrigerator model that is not equipped

with a fan, the refrigerator cooling performance will be poor.

Make sure the refrigerator model is equipped with a fan.

- Install the upper side-wall exhaust vent [24] so that the distance [25] from the bottom of the

enclosure to the top of the rough opening for the upper exhaust vent is at least 63 inches (see

Art01588 and Art01589).

- Align the upper exhaust vent horizontally above the lower intake vent [9].

Install an Upper Side-Wall Exhaust Vent

Install the Baffles for an Upper Side-Wall Exhaust Vent

CAUTION:

Make sure that all horizontal baffles are the full width of

the inside of the enclosure and are in the correct location. If the baffles

are not the full width of the enclosure or incorrectly located, poor cooling

performance can result.

If the enclosure depth is 24 inches or more and less than 26 inches (See

Art01764):

- Install a wood, aluminum or galvanized steel top baffle [13] between the

top of the refrigerator and the top of the upper exhaust vent [24].

- Make sure that the top baffle is less than 1/4 inch [15] from the top of

the refrigerator and baffle overlaps the refrigerator 1 inch or less.

- Make sure that the baffle is against the wall of the vehicle at the top of

the upper exhaust vent and less than 1/4 inch above the opening for

the upper exhaust vent.

- Install an aluminum or galvanized steel bent-sheet condenser baffle [26] .

- Make sure that the bend of the condenser baffle is the full width of the

inside of the enclosure.

Art01600

23

22

!

Art01764

13

25

24

9

26

15

15

!

Advertising