Offset vertical enclosures – Thetford 1210 Series GE - Current Manuel d'utilisation
Page 10

Installation Manual 10
Offset vertical enclosures:
If the enclosure depth is 24 inches or more and less than 25 inches (See Art01783):
- Install an angled top baffle [172] between the top rear edge of the refrigerator and the
inside edge of the upper exhaust vent opening.
- Make sure that the angled top baffle is less than 1/4 inch [15] from the top of the
refrigerator.
- Make sure that the angled top baffle is no more than 45° from vertical [20].
- Install an inside corner baffle [173] between the outside edge of the upper exhaust
vent opening and either the side wall of the vehicle or the solid box baffle (depending
on the vehicle design).
If the enclosure depth is 25 inches or more and less than 26 inches (See Art01784):
- Install an angled top baffle [172] between the top rear edge of the refrigerator and the
inside edge of the upper exhaust vent opening.
- Make sure that the angled top baffle is less than 1/4 inch [15] from the top of the
refrigerator.
- Make sure that the angled top baffle is no more than 45° from vertical [20].
- Install an inside corner baffle [173] between the outside edge of the upper exhaust
vent opening and either the side wall of the vehicle or the solid box baffle (depending
on the vehicle design).
- Install a condenser baffle [16] at the lowest edge of the condenser of the refrigerator.
- Make sure that the condenser baffle is 1 inch or less [19] from the condenser.
- Install an absorber baffle [171] 18 inches to 18 1/2 inches above the bottom of the
enclosure [17] (4 1/4 inches to 4 3/4 inches above the top of the lower intake vent
opening) [18] .
- Make sure that the absorber baffle is 1 inch or less [19] from the absorber.
Art01783
15
20
172
173
Art01784
20
15
172
173
10
16
19
18
17
171
19
11