Tweco 100 Auto-Cut Manuel d'utilisation
Page 18

SPECIFICATIONS 2-2
Manual 0-4764
2.06 Power Supply Specifications & Electrical Requirements
SPECIFICATIONS & DESIGN FEATURES
Max OCV (U
0
)
380 vdc
Max Output Current 100 Amps
Output Voltage
160 vdc
Duty Cycle Rating
100% @ 100A @ 160V (16kW)
Operating range
14°F to 122°F (-10°C to + 50°C)
Power Factor
0.70 @ 100 ADC Output
Cooling
Forced Air (Class F)
Auto-Cut 100 Power Supply
Input
Power Input
Current
Suggested Sizes (See Note)
Voltage
Freq.
3-Ph
3-Ph
Fuse (Amps)
Wire (AWG)
(Volts)
(Hz)
(kVA)
(Amps)
3-Ph
3-Ph
208
50/60
23
64
80
#4
1
230
50/60
24
60
75
#4
1
400
50
28
40
50
#6
1
400 (CE)
50
28
40
50
#6
1
460
50/60
26
33
40
#8
1
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electrical Code
1
Extra Hard Usage Type SO, SOW, SOO, SOOW, ST, STW, STO, STOW, STOO, STOOW
CAUTION
Fuse and wire sizes are for reference only. The installation must conform to national and local codes for the type
and method of wire being used.