Installation

9

Plumbing Connections

DRAIN CONNECTION
The steam vent assemblies are constructed of 2"

DWV copper piping reduced to 1Ć1/2 DWV pipe.
The steam vent should be run to an open floor

drain avoiding flexible hose that could sag and alĆ

low trapped water to accumulate. The customer

must supply the piping from the oven to the drain.
Connect drip pan drain to steam vent with black

flexible hose supplied.
Use the drain vent assembly and a 2" (50.8mm)

pipe for drain connection.

Customer supplied

2" (50.8mm) drain

waste vent piping

Coupling

Figure 6

Specific water/drain connection for City of Los

Angeles
1. Each drain line from the appliance shall be

routed without dips or sags to terminate

above the flood level rim of an approved indiĆ

rect waste receptor.

2. The appliance shall be installed in accordance

with the manufacturer's printed instructions

and the LAPC and LAMC, 1999 editions.

3. A backflow protection device shall be installed

on the potable water system directly ahead of

the appliance. The backflow protection device

shall be any of the following: an approved presĆ

sure type vacuum breaker installed at least 12"

above the highest point of use, a double check

valve backflow preventer or a reduced pressure

principal backflow preventer.