Installation

15

Electrical Connection

Before making any electrical connections to this

unit, check that the power supply is adequate for

the voltage, amperage, and phase requirements

stated on the rating plate.
A wiring diagram accompanies this manual and is

also attached to the inside of the control box.

MT1828G
U.S. and Canadian installations
The MT1828G requires a 15 Amp, 60HZ, 1Φ,

208-240VAC, 4 wire service consisting of L1, L2,

neutral and ground. Wiring from the power source

to these units must be a minimum of #16 AWG

copper stranded wire or larger.
General export and Australian installations
The MT1828G requires a 15 Amp, 50 or 60Hz, 1Φ,

220/240 VAC, 3 wire service consisting of L1, neu-

tral and ground. Use 90_C wire and size wire ac-

cording to local codes.

MT1828E
U.S. and Canadian installations
The MT1828E is available in either 1Φ or 3Φ mod-

els. Single phase models require a 60Hz,

208/240VAC, 3 wire service consisting of L1, L2

and ground. Three phase models require a 60Hz,

208/240VAC, 4 wire service consisting of L1, L2,

L3 and ground. Wiring from the power source to

any of these units must be a minimum of #8 AWG

copper stranded wire or larger for 3 phase and #4

AWG for 1 phase.

General export and Australian installations
The MT1828E is available in either 1Φ or 3Φ mod-

els. Single phase models require a 50 Hz,

220/240VAC, 3 wire service consisting of L1, L2

and ground. Three phase models are available in

either Delta or WYE configurations. Delta models

require 50Hz, 208/240VAC, 4 wire service consist-

ing of L1, L2, L3 and ground. WYE models require

50 Hz, 415/240 VAC, 5 wire service consisting of

L1, L2, L3, neutral and ground. Use a minimum of

8.37 mm

2

copper stranded wire or larger for 3

phase and 21.15 mm

2

for 1 phase.

CAUTION:
Single phase units MUST NOT be connected to

the high phase of a three (3) phase system.

High phase refers to a potential of 240 volts be-

tween one leg and neutral. The remaining two

legs will have a potential of 115 volts between

each phase and neutral. FAILURE TO DO SO

WILL RESULT IN EXTENSIVE DAMAGE TO

ELECTRICAL COMPONENTS AND POSSIBLE

FIRE IN THE CONTROL BOX.
THE BLODGETT OVEN COMPANY CANNOT AS-

SUME RESPONSIBILITY FOR LOSS OR DAMAGE

SUFFERED AS A RESULT OF IMPROPERLY IN-

STALLED UNITS.

WARNING!!
Incorrect wiring will result in extensive

damage to electrical components and

possible fire in the control panel.