2.4 RATING PLATE INFORMATION
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.33-2009, ANSI 21.88-2009 VENTED GAS FIREPLACE HEATER / APPAREIL DE CHAUFFAGE ALIMENTÉ AU GAZ ET VENTILÉ
GAS FIRE VENTED DECORATIVE APPLIANCE. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. CERTIFIED FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS
EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR
MANUFACTURED HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A. THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE (S) OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN AFTER MARKET, PERMANENTLY LOCATED, MANUFACTURED
HOME OR MOBILE HOME, WHERE NOT PROHIBITED BY LOCAL CODES.
FOYER DE CHAUFFAGE AU GAZ AVEC ÉVACUATION. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES AU GAZ, EN VIGUEUR AU CANADA OU AUX ÉTATS-UNIS DE LA NORME DE SECURITÉ ET DE
CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS NE PEUT ÊTRE APPLIQUÉE, SE RÉFÉRER A LA NORME RELATIVE AU CRITÈRE DE MESURES DE
SÉCURITÉ CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES SITES ET LES COMMUNAUTÉS, ANSI/NFPA 501A.
VENTED GAS FIREPLACE NOT FOR USE
WITH SOLID FUEL. FOR USE WITH GLASS
DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING:
DO NOT ADD ANY MATERIAL TO
THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE
MATERIALS:
TOP
0
RECESSED DEPTH 29 1/2"
FLOOR
0
VENT
2"
SIDES
0
MANTEL
4" *
BACK 0
TOP, SIDES & BACK: PER STAND OFF SPACERS FOR
FRAMING MATERIALS. FOR FINISHING MATERIALS
SEE OWNERS MANUAL
* MAXIMUM HORIZONTAL EXTENSION. SEE INSTRUCTION
MANUAL FOR GREATER EXTENSIONS.
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM
AND MAXIMUM VENT LENGTHS.
ELECTRICAL RATING: 115V 0.82AMP, 60HZ
WOLF STEEL LTD.
24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA
UN COMBUSTIBLE SOLIDE NE DOIT PAS
ÊTRÉ UTILISÉ AVEC CET APPAREIL.
UTILISER AVEC LES PORTES VITRÉES
HOMOLOGUÉES SEULEMENT AVEC
CETTE UNITÉ.
AVERTISSEMENT:
N'AJOUTEZ PAS A CET
APPAREIL AUCUN MATÉRIAU DEVANT ENTRER
EN CONTACT AVEC LES FLAMMES AUTRE QUE
CELUI QUI EST FOURNI AVEC CET APPAREIL
PAR LE FABRICANT.
DÉGAGEMENTS MINIMAUX DES MATÉRIAUX
COMBUSTIBLES:
DESSUS
0 PROFONDEUR D'ENCASTRÉ 29 1/2"
PLANCHER 0 ÉVENT
2"
CÔTES
0 MANTEAU
4" *
ARRIÉRE 0
DESSUS, COTÉS & ARRIÈRE: SELON LES ESPACEURS
DE DÉGAGEMENT POUR LES MATÉRIAUX D'OSSATURE
SELON LE MANUEL DE PROPRIÉTAIRE POUR LES
MATÉRIAUX DE FINITION.
* L'EXTENSION HORIZONTALE MAXIMALE: 2". RÉFÉRER
AU MANUEL D'INSTRUCTION POUR DES EXTENSIONS
PLUS GRANDES. RÉFÉRER AU MANUEL D'INSTALLATION
DE PROPRIÉTAIRE.
ALTITUDE / ÉLÉVATION
INPUT / ALIMENTATION
REDUCED INPUT / ALIMENTATION RÉDUITE
0-4500FT (0-1370M)
50, 000 BTU/H
37, 000 BTU/H
3.5" WATER COLUMN/D'UNE COLONNE D'EAU
4.5" WATER COLUMN/D'UNE COLONNE D'EAU
7.0" WATER COLUMN/D'UNE COLONNE D'EAU
0-4500FT (0-1370M)
50, 000 BTU/H
37, 000 BTH/H
10" WATER COLUMN/D'UNE COLONNE D'EAU
11" WATER COLUMN/D'UNE COLONNE D'EAU
13" WATER COLUMN/ D'UNE COLONNE D'EAU
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE
WOLF STEEL VENT KITS. SEE OWNERS INSTALLATION MANUAL
FOR VENTING SPECIFICS. PROPER REINSTALLATION AND
RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR
INTAKE SYSTEM.
L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT L'ENSEMBLE
D'ÉVACUATION PROPRE A WOLF STEEL. RÉFÉRER AU MANUEL
D'INSTALLATION DE PROPRIÉTAIRE POUR L'ÉVACUATION
PRÉCISE. IL EST IMPORTANT DE BIEN RÉINSTALLER ET
RESCELLER L'ÉVENT APRÈS AVOIR ASSURÉ LE MAINTIEN DU
SYSTÉME DE PRISE D'AIR.
CLASSIFICATION: 115V 0.82AMP, 60HZ
W385-0345 / F
GD90NT
GD90PT
SERIAL NUMBER/NO. DE SÉRIE:
GD/BGD90
BGD90NT
BGD90PT
MANIFOLD PRESSURE /
PRESSION AU COLLECTEUR
MINIMUM SUPPLY PRESSURE /
PRESSION D'ALIMENTATION MINIMALE
MAXIMUM SUPPLY PRESSURE /
PRESSION D'ALIMENTATION MAXIMALE
NATURAL MODELS
PROPANE MODELS
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
SAMPLE
E
SAMPLE
SAMPLE
/ APPAREIL DE CHAUFFAGE ALIM
ON IF INSTALLED IN ACCORDANCE WITH
IS US STANDARD IS NOT APPLICA
PLATE AND MAY BE INSTAL
ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DAN
UR AU CANADA OU AUX ÉTATS-UNIS DE LA NORME D
APPLIQUÉE, SE RÉFÉRER A LA NORME RELATIVE
501A.
ADA
DE / ÉLÉVAT
T / ALIMENTATION
INPUT / ALIMENTATION RÉDUIT
EAU
(0-137
NG THE APPROPRIATE
TS. SEE OWNERS INSTALLATION MANUAL
G SPECIFICS. PROPER REINSTALLATION
NECESSARY AFTER SERVICING THE VENT
KE SY
L
SERIAL NUMBER/NO.
PL
90PT
MANIFOLD PRESSURE /
PRESSION AU COLLECTEUR
MINIMUM SUPPLY PRESSURE /
SSION D'ALIMENTATION MINIMALE
AXIMUM SUPPLY PRESS
PRESSION D'ALIMENTATION MA
PROPANE MOD