RECEIVER
SLOT
SPARK MODULE
VALVE
WING NUT
INNER ACCESS
PANEL
A.
Remove access panel from inside the
fi rebox.
B.
Unplug the control module from the junction
box.
C.
Pull up on the control module being held
down with Velcro and disconnect the plugs
(fan, aux). Remove wiring harness from the
front of the casing.
D.
Install the new control module, see
“ELECTRICAL CONNECTION” section.
The valve on The is piped with two fl ex connectors (one inlet, one outlet). It can be removed or pulled
forward for service.
A.
Turn gas off.
B.
Open right control door.
C.
Remove the wing nut and pivot the valve out from the slot at the bottom of the valve.
D.
Slowly pull the valve through the control door being careful not to kink the gas lines or wires.
E.
Disconnect inlet/outlet fl ex connectors, wires and thermocouple.
F.
Remove screws securing gas valve to the mounting bracket.
A.
Open the right control door by pulling
bottom portion away from magnet
catch.
B.
Remove the hearth strip by lifting up
and away from appliance.
C.
The spark module is located in the front
right corner of the appliance (see photo
below).
D.
Disengage the battery compartment
door from the top of module.
E.
Replace battery and re-install compartment door.
CONSTANTLY POWERED 120V OUTLET
FAN OUTLET
120V AUX OUTLET
MAINS VOLTAGE
SUPPLY CORD
MODULE ON/OFF SWITCH
COMMUNICATION BUS (3 PIN)
RECEIVER
SLOT
SPARK MODULE
VALVE
WING NUT
8.4 CONTROL MODULE REMOVAL
8.5 VALVE
REMOVAL
8.6 “AUTO SPARK” BATTERY REMOVAL