Sample, Warning – Napoleon Fireplaces FIBERGLOW GL18E Manuel d'utilisation
Page 5

5
W415-1071 / C / 01.11.12
2.2 GENERAL
INFORMATION
THIS APPLIANCE MUST NOT BE INSTALLED IN A BEDROOM OR BATHROOM.
!
WARNING
2.3 MINIMUM APPLIANCE SIZE
Do not install the gas log set into a cavity smaller than that
referenced in the table.
LOG SET
HEIGHT
WIDTH
DEPTH
GL18
18”
22”
14”
GL24
20”
28”
14”
GL30
22”
34”
14”
GL18
GL24
GL30
NG
LP
NG
LP
NG
LP
Altitude (FT)
0-4,500
0-4,500
0-4,500
0-4,500
0-4,500
0-4,500
Max input (BTU/HR)
55,000
55,000
60,000
60,000
65,000
65,000
Min Inlet Gas Supply Pressure
4.5“ Water
Column
11“ Water
Column
4.5“ Water
Column
11“ Water
Column
4.5“ Water
Column
11“ Water
Column
Max Inlet Gas Supply Pressure
7“ Water
Column
13“ Water
Column
7“ Water
Column
13“ Water
Column
7“ Water
Column
13“ Water
Column
Manifold Pressure (Under Flow
Conditions)
3.5“ Water
Column
10“ Water
Column
3.5“ Water
Column
10“ Water
Column
3.5“ Water
Column
10“ Water
Column
2.4 RATING
PLATE
THE RATING PLATE IS CHAINED TO THE LEG OF THE BURNER BASE AND SHOULD BE TUCKED
UNDER THE ENTIRE ASSEMBLY
SAMPLE
This rating plate illustration is for reference only. Refer to the rating plate on the appliance for accurate
information.
W385-1870
SERIAL NUMBER/NO. DE SERIE:
GLE
REFERENCE # W/N 15987
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: ANSI Z21.60b-2004 CGA 2.26b-2004, DECORATIVE APPLIANCE FOR INSTALLATION IN SOLID-FUEL BURNING APPLIANCES
WOLF STEEL LTD.
24 NAPOLEON ROAD. BARRIE, ONTARIO L4M 0G8 CANADA
WOLF STEEL USA
103 Miller Drive, Crittenden, Kentucky, USA, 41030
18”
20”
22”
GL18 PE
GL24 PE
GL30 PE
GL18 NE
GL24 NE
GL30 NE
C E R T I F I E D
CERTIFIED FOR CANADA/ USA
CERTIFIEE POUR
CANADA/ USA
55,000BTU/h 60,000BTU/h 65,000BTU/h
34,000BTU/h 35,000BTU/h 36,000BTU/h
55,000BTU/h 60,000BTU/h 65,000BTU/h
45,000BTU/h 50,000BTU/h 50,000BTU/h