2.5 RATING PLATE INFORMATION
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
SERIAL NUMBER/NO. DE SERIE:
IR3/CIR3
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE THAT WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
DECORATIVE PRODUCT: NOT FOR USE AS A HEATING APPLIANCE.
AVERTISSEMENT: N'A JOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET
APPAREIL PAR LE FABRICANT.
PRODUIT DÉCORATIF: NE PAS UTILISER COMME APPAREIL DE CHAUFFAGE.
W385-0660 / C
CERTIFIED FOR
CERTIFIEE POUR
CANADA USA
IR3N
IR3P
CIR3N
CIR3P
MODEL
C E R T I F I E D
REFERENCE #161746
Natural Gas/Gaz Naturel
Propane
CE FOYER À GAZ VENTILÉS NE DOIT PAS ÊTRE UTILISÉ
CONJOINTEMENT AVEC DES FILTRES À AIR. UTILISER AVEC LES
PORTES VITRÉES HOMOLOGUÉES AVEC CETTE UNITÉ SEULE-
MENT. UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE
AVEC CET APPAREIL.
CERTIFIED UNDER / HOMOLOGUÉ SELON LES NORMES: ANSI Z21.50b-2009, CSA 2.22b-2009 VENTED GAS FIREPLACE / FOYER À GAS VENTILÉ.
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA
ELECTRICAL RATING: 115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE
OWNER’S INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND
RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
WARNING: FOR INSTALLATION INTO A VENTED NON-COMBUSTIBLE FIREPLACE ONLY. THE
MINIMUM FIREPLACE SIZE IS: HEIGHT 20.5”, DEPTH 13.25”, WIDTH 29”. THE MINIMUM INSIDE
FLUE SIZE IS 6”. THE MINIMUM DISTANCE FROM THE BOTTOM OF A COMBUSTIBLE MANTEL
PROJECTING A MAXIMUM 3” FROM THE WALL TO THE TOP OF THE UNIT IS 12”. SEE OWNER’S
MANUAL FOR GREATER EXTENSIONS.
OPTIONAL FAN KIT - GZ550-KT, GD65.
CLASS : 115V, 1.5AMP, 60HZ
L’APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L’ENSEMBLE D’EVACUATION PROPRE A WOLF STEEL. REFERER
AU MANUEL D’INSTALLATION DE PROPRIETAIRE POUR L’EVACUATION PRECISE. IL EST IMPORTANT DE BIEN
REINSTALLER ET RESCELLER L’EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D’AIR.
ATTENTION : POUR INSTALLATION DANS UN FOYER VENTILE EN MACONNERIE. LES DIMENSIONS MINIMUMS SONT:
HAUTER 19.75”, PROFONDEUR 13.25”, LARGEUR 29”. LE DIAMETRE INTERIEUR MINIMUM DE CONDUIT D’EVACUATION
EST DE 6”. LA DISTANCE MINIMALE, DU BAS DU MANTEAU COMBUSTIBLE FORMANT UNE PROJECTION MAXIMALE DE
3” DU MUR AU DESSUS DE LA GARNITURE NORMALE EST 12”. REFERER AU MANUEL D’INSTALLATION POUR DES
EXTENSIONS PLUS GRANDES.
SOUFFLERIE OPTIONELLE GZ550-KT, GD65.
NE PAS ALLUMER SI DES ENFANTS OU D’AUTRES INDIVIDUS À RISQUE
SONT À PROXIMITÉ DU FOYER. FOYER À GAZ VENTILÉ. HOMOLOGUÉ POUR
INSTALLATION DANS UNE CHAMBRE À COUCHER, UNE SALLE DE BAIN ET
UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE
SI SON INSTALLATION EST CONFORME AUX EXIGENCES DE LA NORME
CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES ÉQUIPÉES AU GAZ, EN
VIGUEUR AU CANADA, OU AUX ÉTATS-UNIS, SELON LA NORME DE
SÉCURITÉ ET DE CONSTRUCTION DE MAISONS MANUFACTURÉES, TITRE
24 CFR, SECTION 3280. DANS LE CAS OÙ CETTE NORME DES ÉTATS-UNIS
NE PEUT ÊTRE APPLIQUÉE, SE RÉFÉRER À LA NORME RELATIVE AU
CRITÈRE DE MESURES DE SÉCURITÉ CONTRE L'INCENDIE POUR LES
INSTALLATIONS DANS LES MAISONS MANUFACTURÉES, LES SITES ET LES
COMMUNAUTÉS, ANSI/NFPA 501A.
DO NOT TURN ON IF CHILDREN OR OTHER AT RISK INDIVIDUALS
ARE NEAR THE FIREPLACE. DIRECT VENT GAS FIREPLACE.
SUITABLE FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF
INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD
CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN
CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280.
WHEN THIS US STANDARD IS NOT APPLICABLE USE THE
STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED
HOME INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA
501A.
4500FT (0-1370m)
ALTITUDE/ELEVATION
4500FT (0-1370m)
24,000 BTU/h
INPUT/ALIMENTATION
24,000 BTU/h
18,000 BTU/h
REDUCED INPUT/ALIMENTATION REDUITE
18,000 BTU/h
MANIFOLD PRESSURE: 3.5” WATER COLUMN
PRESSION AU COLLECTEUR: 3.5” D’UNE COLONNE D’EAU
MINIMUM SUPPLY PRESSURE: 4.5” WATER COLUMN
PRESSION D’ALIMENTATION MINIMALE: 4.5” D’UNE COLONNE D’EAU
MAXIMUM SUPPLY PRESSURE: 7.0” WATER COLUMN
PERSSION D’ALIMENTATION MAXIMALE: 7.0” D’UNE COLONNE D’EAU
P4: 64.2%
MANIFOLD PRESSURE: 10” WATER COLUMN
PRESSION AU COLLECTEUR: 10” D’UNE COLONNE D’EAU
MINIMUM SUPPLY PRESSURE: 11” WATER COLUMN
PRESSION D’ALIMENTATION MINIMALE: 11” D’UNE COLONNE D’EAU
MAXIMUM SUPPLY PRESSURE: 13” WATER COLUMN
PERSSION D’ALIMENTATION MAXIMALE: 13” D’UNE COLONNE D’EAU
P4: 64.2%
THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE
WITH AIR FILTERS. FOR USE WITH GLASS DOORS CERTIFIED
FOR THIS UNIT ONLY. NOT FOR USE WITH SOLID FUEL.
SAMPLE
HE APPLIANCE THAT WILL COME IN
THAT WILL COME IN
N THAT SUPPLIED BY THE MANUFACTURE
N THAT SUPPLIED BY THE MANUFACTUR
SE AS A HEATING APPLIANCE.
SE AS A HEATING APPLIANCE.
DA USA
A USA
PL
IR3P
IR3P
MODEL
MODEL
SAMPLE
1746
P
CE F
C
CO
C
FIREPLACE / FOY
IREPLACE / FO
EL LTD.
L LTD.
N ROAD, BARRIE. ON
ROAD, BARRIE. O
0HZ
USING THE APPROPRIATE WOLF STEEL VEN
THE APPROPRIATE WOLF STEEL V
AL FOR VENTING SPECIFICS. PROPER REINS
TING SPECIFICS. PROPER REINS
FTER SERVICING THE VENT-AIR INTAKE SYS
G THE VENT-AIR INTAKE SYS
ON INTO A VENTED NON-COMBUSTIBLE FIRE
N INTO A VENTED NON-COMBUSTIBLE FIR
ZE IS: HEIGHT 20.5”, DEPTH 13.25”, WIDTH 29”
ZE IS: HEIGHT 20.5”, DEPTH 13.25”, WI
MINIMUM DISTANCE FROM THE BOTTOM OF A
MINIMUM DISTANCE FROM THE BOTTO
XIMUM 3” FROM THE WALL TO THE TOP OF TH
IMUM 3” FROM THE WALL TO THE TOP O
EATER EXTENSIONS.
ATER EXTENSIONS.
N KIT - GZ550-KT, GD65.
T - GZ550-KT, GD65.
UMER SI DES ENFANTS
UMER SI DES ENFAN
ROXIMITÉ DU FOYER. FOY
ROXIMITÉ DU FOYER. F
LLATION DANS UNE CHAMBRE À
LATION DANS UNE CHAMBRE À
STUDIO. APPROPRIÉ POUR INSTALLAT
UDIO. APPROPRIÉ POUR INSTALLAT
SON INSTALLATION EST CONFORME AUX
STALLATION EST CONFORME AU
CAN/CSA Z240MH SÉRIE DE MAISONS MO
40MH SÉRIE DE MAISONS MO
VIGUEUR AU CANADA, OU AUX ÉTATS-
CANADA, OU AUX ÉTATS-
SÉCURITÉ ET DE CONSTRUCTION D
CONSTRUCTION D
24 CFR, SECTION 3280. DANS LE C
280. DANS LE
NE PEUT ÊTRE APPLIQUÉE, SE
NE PEUT ÊTRE APPLIQUÉE, SE
CRITÈRE DE MESURES DE SÉ
CRITÈRE DE MESURES DE S
INSTALLATIONS DANS LES
INSTALLATIONS DANS L
COMMUNAUTÉS, ANSI/N
COMMUNAUTÉS, ANSI/N
ITUDE/ELEVATION
45
TUDE/ELEVATION
4
PUT/ALIMENTATION
PUT/ALIMENTATION
D INPUT/ALIMENTATION REDUITE
NPUT/ALIMENTATION RE
TER COLUMN
ER COLUMN
OLONNE D’EAU
OLONNE D’EAU
” WATER COLUMN
WATER CO
NE COLONNE D’EAU
E COLONNE D’E
E: 7.0” WATER COLUMN
0” WATER COLUMN
” D’UNE COLONNE D’EAU
COLONNE D’EAU
P4:
P4:
64.2%
64.2%
MANIFOLD PRESSURE
MANIFO
PRESSION AU COLL
PRESS
MINIMUM SUPPLY
MINIMUM
PRESSION D’AL
PRESSION
MAXIMUM SU
MAXIMUM S
PERSSION
ERSSION
P4: 64.2%
64.2
R IS NOT FOR USE
R IS NOT FOR USE
GLASS DOORS CERTIFIED
LASS DOORS CERTIFIED
SE WITH SOLID FUEL.
TH SOLID FUEL.