Napoleon Fireplaces XIR4 Manuel d'utilisation
Page 6

W415-1194 / A / 12.19.13
6
EN
2.4 GENERAL
INFORMATION
4.12A
sealed combustion product.
The installation must conform with local codes or, in
absence of local codes, the National Gas and Propane
Installation Code CSA B149.1 in Canada, or the National
Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United
States. Suitable for mobile home installation if installed in
accordance with the current standard CAN/CSA Z240MH
Series, for gas equipped mobile homes, in Canada or
ANSI Z223.1 and NFPA 54 in the United States.
Some appliances have optional fans or blowers. If an optional fan or blower is installed, the junction box must
be electrically connected and grounded in accordance with local codes, use the current CSA C22.1 Canadian
Electrical Code in Canada or the ANSI/NFPA 70 National Electrical code in the United States.
We suggest that our gas
hearth products be installed
and serviced by professionals
who are certified in the U.S.
by the National Fireplace
Institute
® (NFI) as NFI Gas
Specialists
www.nficertified.org
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
XIR4-1
NG
LP
Altitude (FT)
0-4,500
0-4,500
Max. Input (BTU/HR)
40,000
40,000
Max. Output (BTU/HR)
33,200
33,200
Effi ciency (w/the fan on)
83%
83%
A.F.U.E. (maximum value)
79%
79%
Min. Inlet Gas Supply Pressure
4.5" Water Column
(11mb)
11" Water Column
(27mb)
Max. Inlet Gas Supply Pressure
7" Water Column
(17mb)
13" Water Column
(32mb)
Manifold Pressure (Under Flow Conditions)
3.5" Water Column
(9mb)
10" Water Column
(25mb)