Warning – Napoleon Fireplaces XIR4 Manuel d'utilisation
Page 12

W415-1194 / A / 12.19.13
12
EN
!
WARNING
GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.
THE DOOR LATCHES ARE PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED. DO
NOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED.
FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIR
OPENINGS, LOUVRES OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR
SERVICE. OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS.
BEFORE DOOR IS REMOVED TURN THE APPLIANCE OFF AND WAIT UNTIL APPLIANCE IS COOL TO
THE TOUCH. DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE.
75.1
A.
There are 2 latches on the top of each door.
B.
Using the tool provided, pull the latch
forward and upwards, out of the slot in the
door, as shown. Ensure to keep one hand
on the door at all times, to prevent it from
falling on the fl oor.
C.
When both latches have been released tilt
the door forward and out of the bottom door
retainer.
D.
Reverse this process to install the door.
IMPORTANT: Once latches are engaged,
test that the door is secure and will not
fall forward before letting go.
THE LATCHES ARE SHOWN IN THE ILLUSTRATION BELOW.
LATCHES
4.2 DOOR REMOVAL / INSTALLATION
TOP OF
APPLIANCE
WARNING: Non-combustible facing material may protrude from the top, and/or sides of this appliance,
as illustrated [up to a maximum of 6” (152.4mm)]. Greater than 6” (152.4mm) protrusions are considered a
mantel and must meet the combustible mantel requirements.
71.4B
4" (102mm)
2" (51mm)
6" (152mm)
FRONT OF
APPLIANCE
4" (102mm)
2" (51mm)
NON-COMBUSTIBLE
FACING MATERIAL
TOP VIEW
SIDE VIEW
0" (0mm)
FINISH
MATERIAL
NON-COMBUSTIBLE
FACING MATERIAL
FINISH MATERIAL
2" (51mm)
4" (102mm)
6" (152mm)
4" (102mm)
2" (51mm)
0" (0mm)
4.3 NON-COMBUSTIBLE FACING MATERIAL