2.4 RATING PLATE INFORMATION
A
4"
B
2"
C
2"
W385-0330 / E
NOT FOR USE WITH SOLID FUEL
GDS/CDVS25
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.33-2009, ANSI Z21.88-2009 VENTED GAS FIREPLACE HEATER / FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL:
VENT TOP
2" TO CEILING FROM
VENT BOTTOM
1" STOVE TOP 48”
VENT SIDES
1"
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE
UTILSE AVEC CET APPAREIL
EVENT SUPERIEUR 2" ENTRE LE DESSUS
DU FOYER
EVENT INFERIEUR 1" ET LE PLAFOND 48”
COTES DE L'EVENT 1"
A
4"
B
2"
C
2"
DEGAGEMENTS MINIMAUX DES MATERIAUX
COMBUSTIBLES:
SERIAL NUMBER / NO. DESERIE
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION.
SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH
THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE
HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME
CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN
THIS US STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE
SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND
COMMUNITIES, ANSI / NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE
BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA
Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU
CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE ET DE
CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280.
DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE
REFERER A LA NORME RELATIVE AU CRITERE DE MESURES DE SECURITE
CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS
MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
MANIFOLD PRESSURE: 3.5” W.C. (NG)
PRESSION AU COLLECTEUR: 3.5" D'UNE
COLONNE D'EAU(GN)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG)
PRESSION D'ALIMENTATION MIN: 4.5"
D'UNE COLONNE D'EAU (GN)
MAX. SUPPLY PRESSURE: 7" W.C. (NG)
PRESSION D'ALIMENTATION MAX: 7"
D'UNE COLONNE D'EAU (GN)
AFUE: 64%
MANIFOLD PRESSURE: 10” W.C. (LP)
PRESSION AU COLLECTEUR: 10" D'UNE
COLONNE D'EAU(P)
MIN SUPPLY PRESSURE: 11" W.C.(LP)
PRESSION D'ALIMENTATION MIN: 11"
D'UNE COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 13"
D'UNE COLONNE D'EAU (P)
AFUE: 64%
GDS25N
MODEL
GDS25P
0-2000ft
2000-4500ft
ALTITUDE / ELEVATION 0-2000ft
2000-4500ft
24,500 BTU/h
22,000 BTU/h
INPUT / ALIMENTATION
23,000 BTU/h
20,000 BTU/h
19,000 BTU/h
16,000 BTU/h
REDUCED INPUT /
16,000 BTU/h
14,000 BTU/h
ALIMENTATION REDUITE
9700539 (WSL)
4001657 (NGZ)
4001658
(NAC)
4001659
(WUSA)
FOR USE WITH GLASS DOORS CERTIFIED
WITH THIS UNIT ONLY.
WARNING: DO NOT ADD ANY MATERIAL TO
THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN
THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
ELECTRICAL RATING: 115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING
THE APPROPRIATE WOLF STEEL VENT
KITS. SEE OWNERS INSTALLATION MANUAL
FOR VENTING SPECIFICS. MINIMUM AND
MAXIMUM VERTICAL VENT LENGTHS ARE 3
FEET AND 40 FEET RESPECTIVELY.
MINIMUM AND MAXIMUM HORIZONTAL
VENT LENGTHS ARE 10 INCHES AND 20
FEET RESPECTIVELY. PROPER REINSTAL-
LATION AND RESEALING IS NECESSARY
AFTER SERVICING THE VENT-AIR INTAKE
SYSTEM.
UTILISER AVEC LES PORTES VITREES
HOMOLOGUEES SEULEMENT AVEC CETTE
UNITE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET
APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC
CET APPAREIL PAR LE FABRICANT.
CLASS.: 115V 1.5AMP 60HZ L'APPAREIL
DOIT EVACUER SES GAZ EN UTILISANT
L'ENSEMBLE D'EVACUATION PROPRE A
WOLF STEEL. REFERER AU MANUEL
D'INSTALLATION DE PROPRIETAIRE POUR
L'EVACUATION PRECISE. LES LONGUEURS
VERTICALES MINIMALES ET MAXIMALES
SONT3 PIEDS ET 40 PIEDS
RESPECTIVEMENT.
LES LONGUEURS HORIZONTALES MINIMALES ET
MAXIMALES SONT 10 POUCES ET 20 PIEDS
RESPECTIVEMENT.
IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE
MAINTIEN DU SYSTEME DE PRISE D'AIR.
INSTALLER:
It is your responsibility to check off the appropriate box on the rating plate according to the
model, venting and gas type of the unit.
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for referece only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
S
SS
SAMPLE
AA
SA
SA
SAAAAAAAAAAAAAAAAAAAAAAAA
SAAAA
2
2"
FOYER
ANCE TO COMBUSTIBLE MATER
VENT TOP
2" TO
VENT BOTTOM
1"
VENT SIDES
4M 0G8 CAN
UN COMBU
UTILS
TION DANS
PRIE POUR INS
N CONFORME AU
E MAISONS MOBILES EQ
ETATS-UNIS DE LA
AISONS MANUFACTU
E NORME D'ETAT
ER A LA NORME RELATIVE AU
RE L'INCENDIE POUR LES
MANUFACTURES, LES SI
L
25P
ELEVATION 0-2000ft
ALIMENTATION
DUCED INPUT /
MENTATION REDUITE
4001657 (NGZ)
4001659 (WUSA)
PP
ZONTAL
S AND 20
EINSTAL-
ARY
HE VENT-AIR INTAKE
UTILISER
MO
U
A
PL
PL
W415-0547 / J / 07.16.13
7
EN