Sample, 3 general information, 4 rating plate information – Napoleon Fireplaces GSS42 Manuel d'utilisation
Page 5: Rates and efficiencies

5
W415-0617 / E / 06.13.12
GSS42
W385-0376 / D
CERTIFIED UNDER / HOMOLOGUÉ SELON LES NORMES: CGA CR97-003 (July, 1997) CSA US Req. 4-96, 3rd Ed. OUTDOOR GAS FIREPLACE / FOYER AU GAZ EXTÉRIEUR
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
IF APPLIANCE HAS BEEN SUPPLIED WITH A GAS PRESSURE REGULATOR, IT MUST BE USED. THE
GAS SUPPLY MUST BE TURNED OFF AT THE LP-GAS SYPPLY CYLINDER WHEN THIS APPLIANCE IS
NOT IN USE. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND
LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S MANUAL PROVIDED
WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION, CONSULT A
QUALIFIED INSTALLER, SERVICE AGENCY OR GAS SUPPLIER. MUST NOT BE USED FOR
COOKING. FOR OUTDOOR USE ONLY. IF STORED INDOORS, DETACH AND LEAVE CYLINDER
OUTDOORS.
SI L’APPAREIL EST ÉQUIPÉ D’UN RÉGULATEUR DE PRESSION D’ALIMENTATION, IL DOIT ÊTRE
UTILISÉ. LORSQUE CET APPAREIL N’EST PAS UTILISÉ, VOUS DEVEZ FERMER L’ALIMENTATION EN
GAZ SUR LA BONBONNE DE PROPANE. N’ENTREPOSEZ PAS ET N’UTILISEZ PAS D’ESSENCE
OU AUTRES LIQUIDES ET VAPEURS INFLAMMABLES À PROXIMITÉ DE CET APPAREIL OU TOUT
AUTRE APPAREIL. UNE INSTALLATION NON CONFORME, DES AJUSTEMENTS, DES
ALTÉRATIONS, UN SERVICE OU UN ENTRETIEN INADÉQUATS PEUVENT CAUSER DES
DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES CORPORELLES. RÉFÉREZ-VOUS AU
MANUEL D’INSTRUCTIONS FOURNI AVEC CET APPAREIL. POUR DE L’ASSISTANCE OU POUR
PLUS D’INFORMATION, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE AGENCE D’ENTRETIEN
OU LE FOURNISSEUR DE GAZ. NE PAS UTILISER POUR LA CUISSON. POUR USAGE
EXTÉTIEUR SEULEMENT. SI ENTREPOSÉ À L’INTÉRIEUR, DÉTACHER LA BONBONNE DE
PROPANE ET LA LAISSER À L’EXTÉRIEUR.
9700539 (WSL)
4001657 (NGZ)
4001658
(NAC)
4001659
(WUSA)
GSS42N
MODEL
GSS42P
0-4500FT (0-1370m)
ALTITUDE / ÉLÉVATION
0-4500FT (0-1370m)
65,000 BTU/h
INPUT / ALIMENTATION
65,000 BTU/h
40,000 BTU/h
REDUCED INPUT / ALIMENTATION RÉDUITE
50,000 BTU/h
MANIFOLD PRESSURE: 3.5" WATER COLUMN
MANIFOLD PRESSURE: 10" WATER COLUMN
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU
PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU
NOT FOR USE WITH SOLID FUEL.
WARNING:
THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE.
REPLACE ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN CONTACT WITH THE
FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS:
TOP 18”
BACK
1”
FLOOR 0“
MANTEL
NON-COMBUSTIBLE
SIDES 1”
SEE INSTALLATION INSTRUCTIONS FOR FRAMING CLEARANCES.
UN COMBUSTIBLE SOLIDE NE DOIT PAS ÊTRE UTILISÉ
AVEC CET APPAREIL
AVERTISSEMENT:
CE FOYER UTILISE ET REQUIERT UN THERMOCOUPLE À ACTION
RAPIDE. REPLACEZ UNIQUEMENT AVEC UN THERMOCOUPLE À ACTION RAPIDE DE WOLF STEEL
LTÉE. N'AJOUTEZ PAS A CET APPAREIL AUCUN MATÉRIAUX DEVANT ENTRER EN CONTACT AVEC
LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
DÉGAGEMENTS MINIMAUX DES MATÉRIAUX COMBUSTIBLES:
DESSUS 18”
ARRIÈRE
1”
PLANCHER 0“
MANTEAU
INCOMBUSTIBLE
CÔTÉS 1”
POUR LES DÉGAGEMENTS AUX MATÉRIAUX D’OSSATURE, VOIR LE MANUEL D’INSTRUCTIONS.
SERIAL NUMBER/NO. DE SÉRIE:
D
2.3 GENERAL
INFORMATION
* When the appliance is installed at elevations above 2,000ft, and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of
4% for each additional 1,000ft.
It is highly recommended to protect the logs from moisture (rain, snow). Cover the enclosure opening when not
in use.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certifi ed kit is used.
No external electricity (110 volts or 24 volts) is required for the gas system operation.
Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The appliance must be
isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
When the appliance is installed directly on combustible material other than wood fl ooring, the appliance shall
be installed on a metal or wood panel extending the full width and depth.
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION
AND QUALITY!
RATES AND EFFICIENCIES
NATURAL GAS
PROPANE GAS
Altitude
0 - 2,000*
0 - 2,000*
Maximum Input
65,000 BTU/hr
65,000 BTU/hr
Minimum Inlet Gas Supply Pressure
4.5” Water Column
11” Water Column
Maximum Inlet Gas Supply Pressure
7” Water Column
13” Water Column
Manifold Pressure Under Flow Conditions
3.5” Water Column
10” Water Column
2.4 RATING PLATE INFORMATION
SAMPLE
SAMPLE
GAS FIREP
GAS FIRE
M 0G8 CANA
M 0G8 CANA
D’UN RÉGULAT
D’UN RÉGULA
APPAREIL N’EST PAS U
PPAREIL N’EST PAS
ONNE DE PROPANE. N’E
ONNE DE PROPANE.
UIDES ET VAPEURS INFLAMMA
DES ET VAPEURS INFLAMMA
REIL. UNE INSTALLATION NON
UNE INSTALLATION NO
NS, UN SERVICE OU UN ENTRET
ERVICE OU UN ENTRE
GES À LA PROPRIÉTÉ OU DES BLE
PRIÉTÉ OU DES BL
EL D’INSTRUCTIONS FOURNI AVEC C
L D’INSTRUCTIONS FOURNI AVEC
S D’INFORMATION, CONSULTEZ UN I
S D’INFORMATION, CONSULTEZ UN
U LE FOURNISSEUR DE GAZ. N
U LE FOURNISSEUR DE GAZ. N
EXTÉTIEUR SEULEMENT. SI ENT
TÉTIEUR SEULEMENT. SI ENT
4001657 (NGZ)
4001657 (NGZ)
4001659 (WUSA)
4001659 (WUSA)
PP
MODEL
MODEL
GSS42
SS4
TUDE / ÉLÉVATION
E / ÉLÉVATION
0-45
PUT / ALIMENTATION
PUT / ALIMENTATION
65
D INPUT / ALIMENTATION RÉDUITE
INPUT / ALIMENTATION RÉ
PL
ER COLUMN
R COLUMN
MANIFOLD PRESS
NIFOLD PRE
OLONNE D'EAU
NE D'EAU
PRESSION AU C
PRESSION AU
WATER COLUMN
WATER COLUMN
MINIMUM SU
MINIMUM SU
NE COLONNE D'EAU
E COLONNE D'EAU
PRESSION
PRESS
: 7.0" WATER COLUMN
7.0" WATER COLUMN
MAXIMU
MAXIM
" D'UNE COLONNE D'EAU
UNE COLONNE D'EAU
PRES
PRES
ACTING THERMOCOUPLE.
CTING THERMOCOU
LIED BY WOLF STEEL LTD.
BY WOLF STEEL LTD.
ILL COME
E IN CONTACT WITH THE
IN CONTACT WITH THE
CTURER WITH THE APPLIANCE.
TH THE APPLIANCE.
S:
S:
NON-COM
NON-CO
MING CLEARANCES.
NG CLEARANC
U
For rating plate location, see “INSTALLATION OVERVIEW” section.
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.