WARNING
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
CLEARLY MAINTAINED.
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
HEAT RESISTANT TO PREVENT DISCOLOURATION.
73.1
4.3 MINIMUM MANTEL CLEARANCES
We recommend all mantels made from non-combustible material. If using combustible materials, follow the
chart below.
NOTE: Mantel temperatures will rise above normal temperatures
and may be hot to the touch.
4.4 NAILING
TAB
TOP OF
FIREPLACE
8” MANTEL
6”
4”
2”
30”28”
26”
24”
35 3/4”
28
26
24
4
2
30
32
8
6
10
MANTEL
DEPTH
MANTEL
HEIGHT
To install the appliance face fl ush with the fi nished
surface, position the framework to accommodate the
thickness of the fi nished surface. Bend out the six
nailing tabs, attached on top and on either side of the
appliance and secure to the 2x4 framing. The tabs will
facilitate the installation of either a
1
/
2
” or
3
/
4
” fi nished
surface thickness.