* Within the appliance enclosure a minimum 3” (76mm) clearance between the top of the vent pipe and
combustible materials is required. All other clearances within the enclosure, including where the vent pipe exits
the enclosure are subject to 2” (51mm)to the sides and bottom and 3” (76mm) to the top for horizontal and 2”
(51mm) for vertical.

** See venting section.

NOTE: THIS APPLIANCE IS NOT LOAD BEARING.

IMPORTANT: The fi restop assembly provided must be used when the vent pipes pass through any
walls or are terminated horizontally.

IMPORTANT:

The BHD4 requires a minimum inside enclosure height of 50" (1270mm), measured from the

bottom of the appliance. For temperature requirements, this area must be left unobstructed.

!

WARNING

THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., AS LONG AS THESE MATERIALS NEVER OVERHANG

INTO THE APPLIANCE OPENING.

COMBUSTIBLE

NON-COMBUSTIBLE

BRICK

3" [76mm]

2"

[51mm]

FIRESTOP

43"

[1092mm]
MINIMUM

RISE

50"

[1270mm]
MINIMUM

ENCLOSURE

46" [1168mm]

6" [152mm]

MINIMUM WALL

SEE THRU ONLY

38 1/2"

[978mm]

11 1/2"

[292mm]

5.2 MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES