STEINEL IS D360-120 Manuel d'utilisation

Page 5

Advertising
background image

www.steinel.net

(800) 852-4343

www.steinel.net

(800) 852-4343

Wiring

When installing, make sure power
has been switched off at the
breaker and check that the circuit
is dead with a voltage tester.

Black - Hot

White - Neutral

2 Red - Relay

Standard wiring:

Connect Black and one of
the Red wires to Hot (120VAC
input)

Connect White to Neutral

Connect other Red to Load
(120VAC output)

8

Operation

The IS D360-120 turns lighting on
and off automatically based on
occupancy. Adding a wall switch
provides manual on/off control.

Sensor operation

• Switch light ON (when light is

OFF): Turn switch OFF and ON
once. Light stays ON for the
period selected.

• Switch light OFF (when light

is ON): Turn switch OFF and
ON once. The light turns off or
switches to sensor mode.

Manual override

• Activate manual override: Turn

switch OFF and ON twice.
The lamp is set to stay on for
4 hours (red LED lights up
behind the lens). Then it returns
automatically to sensor mode
(red LED off).

• Deactivate manual override:

Turn switch OFF and ON once.
The light goes out or switches
over to sensor mode.

Light level function

The sensors incorporate a built-in
light level sensor which keeps
lighting off during daylight hours,
regardless of occupancy.

1 x

5 sec. – 20 min

2 x

4 h

9

Neutral

Hot

Black (Line)

Red (Relay)

White (Neutral)

Red (Relay)

L
O
A
D

Advertising