Mounting
Placement guidelines
• Detection lens must have a
clear, unobstructed view of
detection area; it does not
detect from behind obstacles,
such as walls or panes of
glass
• Ideal mounting height is 8-12
feet
• The site of installation should
be at least 20 inches away
from another light because
heat radiated from it may
activate the system
1
1
1
3
6
8
7
1
4
1
4
4
1
5
5
6
Installation
Confi rm power is off at the circuit
breaker.
• Depress the (2) catch (see
page 4) and separate the (3)
switching module from the (4)
sensor module
• Place the (3) switching module
in the (1) fi tting frame and
secure with the (6) securing
spring
• Pull back the springs of the
fi tting frame and place through
2 7/8 inch (73 mm) hole in
fi xture / mounting location
• Connect wiring
• Select desired time delay and
light level settings and snap the
sensor module back into the
switching module
7