Format de sortie – HP Module Fibre Channel Virtual Connect 8 Gb 20 ports pour HP BladeSystem classe C Manuel d'utilisation
Page 150

->help devicebay
General Enclosure Device Bay settings and information
Supported Subcommands:
help
show
-----------------------------------------------------------------------
->show devicebay -help
Description :
This command displays all device bays in the domain
Syntaxe :
show devicebay [<DeviceBayName> | *]
Parameters:
DeviceBayName: The reference name of a device bay in the domain.
The format of the device bay name is
<EnclosureID:DeviceBay>
Exemples :
- Display a summary listing of all device bays:
->show devicebay
- Show detailed information for all device bays:
->show device bay *
- Show detailed information for a specific device bay 2 of
a specific enclosure:
->show devicebay enc0:2
Format de sortie
L'interface CLI propose deux formats de sortie distincts :
●
Format de sortie interactif pour l'utilisateur
●
Format de sortie sous forme de script
Le format de sortie interactif pour l'utilisateur est le format par défaut. Cependant, en utilisant une
option de ligne de commande, vous pouvez également spécifier un format de sortie facile à analyser,
FRWW
Format de sortie 143
- Module Ethernet HP Virtual Connect Flex-10 10 Go pour BladeSystem classe C Module Fibre Channel Virtual Connect 8 Gb 24 ports pour HP BladeSystem classe C Module Ethernet Virtual Connect 1.10 Go pour HP BladeSystem classe C Module HP Virtual Connect FlexFabric 10 Gbits24 ports pour BladeSystem classe C Module Fibre Channel Virtual Connect 4 Gb pour HP BladeSystem classe C Module Fibre Channel Virtual Connect 4 Go pour HP BladeSystem classe C