Installation, Spécifications techniques - power wave – Lincoln Electric IM713 POWER WAVE 655R Manuel d'utilisation
Page 8

A-1
INSTALLATION
POWER WAVE
®
655/R
A-1
SPÉCIFICATIONS TECHNIQUES - POWER WAVE
®
655/R (K1519-1, K1519-2)
SORTIE
TAILLES RECOMMANDÉES DE CÂBLES DʼENTRÉE ET DE FUSIBLES
DIMENSIONS PHYSIQUES
REGISTRES DE TEMPÉRATURES
ENTRÉE À SORTIE NOMINALE – UNIQUEMENT TRIPHASÉE
VOLTS
DʼENTRÉE -
FRÉQUENCE
460/575V - 60HZ.
400V - 50HZ.
460/575V - 60HZ.
–NUMÉROS CODES
10630
10863
11410
11880
TENSION DE
CIRCUIT
OUVERT
75 VDC
TENSION
DʼENTREE /
FREQUENCE
460V - 60HZ.
575V - 60HZ.
HAUTEUR
26.10 in
663 mm
LARGEUR
19.86 in
505 mm
PROFONDEUR
32.88 in
835 mm
POIDS
306 lbs.
139 kg.
TAILLE DE FUSIBLE
SUPERLAG DE TYPE
75OC OU DISJONC-
TEUR (AMPS)
70
60
FIL DE TERRE DE
TYPE 75OC DANS
CONDUIT TAILLES
AWG (MM2)
8 (10)
10 (6)
FIL EN CUIVRE DE
TYPE 75OC DANS
CONDUIT TAILLES
AWG (MM2)
6 (16)
6(16)
REGISTRE DE COURANT PAR PROCÉDÉ
MIG/MAG
FCAW
SMAW
Impulsions
COURANT
50-815 Amps en Moyenne
40-815 Amps en Moyenne
30-600 Amps en Moyenne
15-880 Amps de Crête
FRÉQUENCE
DES IMPUL-
SIONS
5 - 55 VDC
PUISSANCE AUXILIAIRE
(PROTÉGÉE)
40 VDC À
10 AMPS
110 VAC À
10 AMPS
REGISTRE DE
TENSION DES
IMPULSIONS
100 MICRO SEC. -
3.3 SEC.
CURRENT
RANGE
20-815
REGISTRE DE
COURANT
0.15 - 1000 Hz
COURANT
DʼENTRÉE
AMPS
43/34
53/42
40
51
41/33
53/42
PUIS-
SANCE AU
RALENTI
400 Watts
Max.
FACTEUR DE PUIS-
SANCE À SORTIE
NOMINALE
.95 MIN.
EFFICACITÉ
À SORTIE
NOMINAL
84%
CONDITIONS DE
SORTIE
815A@44V. 60%
675A@44V. 60%
815A@44V. 60%
REGISTRE DE TEMPÉRATURE DE FONCTION-
NEMENT
-20°C à + 40°C
REGISTRE DE TEMPÉRATURE DʼENTREPOSAGE-
40°C à + 40°C