A-8
INSTALLATION
LN-7 & LN-7 GMA
A-8
FIGURE A.6 – LN-7 ET LN-7 GMA AUX SOURCES DE COURANT CV/CVI AVEC CONNECTEUR TWIST-
MATE ET AMPHENOL 14 CONTACTS/TÉLÉCOMMANDE – SCHÉMA DE CONNEXION.
CLEVELAND, OHIO U.S.A
–
+
UN CHOC
ÉLECTRIQUE PEUT
ÊTRE MORTEL
AVERTISSEMENT
COUPER L’ALIMENTATION DE LA
SOURCE DE COURANT DE SOUDAGE
EN UTILISANT LE SECTIONNEUR
DANS LA BOÎTE DES FUSIBLES AVANT
DE CONNECTER LE DÉVIDOIR.
SEUL UN PERSONNEL QUALIFIÉ DOIT
INSTALLER, UTILISER, ENTRETENIR
OU RÉPARER CE MATÉRIEL.
N.A. LE CBLE DE SOUDAGE DOIT ÊTRE DE LA GROSSEUR CORRESPONDANT AU COURANT ET AU FACTEUR DE MARCHE D’APPLICATION.
N.B. LE SCHÉMA MONTRE L’ÉLECTRODE POSITIVE. POUR CHANGER DE POLARITÉ, COUPER L’ALIMENTATION.
N.C. L’UTILISATION DE LA TÉLÉCOMMANDE K857 NÉCESSITE L’INSTALLATION D’UN ADAPTATEUR DE TÉLÉCOMMANDE K864 AU CONNECTEUR
AMPHENOL À 14 CONTACTS DE LA SOURCE DE COURANT. ON PEUT CONNECTER LE CBLE D’ENTRÉE K480 DIRECTEMENT À LA SOURCE DE
COURANT SI L’ON N’A PAS BESOIN DE TÉLÉCOMMANDE.
SOURCE DE
COURANT CV/CV-I
AMPHENOL
14 CONTACTS
TÉLÉCOMMANDE
K857 EN OPTION
DÉVIDOIR
LN-7 GMA
ADAPTATEUR DE TÉLÉCOMMANDE
K864 EN OPTION
N.E.
VERS PIÈCE
CÂBLE ÉLECTRODE