INVERTEC STT II

A-1

INSTALLATION

A-1

TENSION NORMALE

COURANT DʼENTRÉE À RÉGIME DE SORTIE

208/230/460/3/60 HZ

32/30/16

200/220/380/415/440/3/50/60 HZ

33/30/18/17/16

SPÉCIFICATIONS TECHNIQUES –Invertec STT II (Pour Code 11092 et ci-dessous)

ENTRÉE - MONOPHASIQUE UNIQUEMENT

RÉGIME DE SORTIE

TAILLES DE FILS DʼENTRÉE ET DE FUSIBLES RECOMMANDÉES

TENSION DʼENTRÉE

TAILLES DE FUSIBLES

RÉGIME AMPÉRAGE

TAILLES DE FILS

TAILLES DE FILS

ET FRÉQUENCE

(SUPER LAG) OU DE

DʼENTRÉE SUR

DʼALIMENTATION EN

DE TERRE EN

DISJONCTEUR

PLAQUE NOMINATIVE

CUIVRE DE TYPE 75ºC

CUIVRE DE TYPE

DANS CONDUIT

75ºC DANS

AWG (IEC)

CONDUIT AWG (IEC)

208/60

40

32

230/60

40

30

460/60

30

16

200/50/60

40

33

220/50/60

40

30

10 (6 mm2)

10 (6 mm2)

380/50/60

30

18

415/50/60

30

17

440/50/60

30

16

HAUTEUR

LARGEUR

PROFONDEUR

POIDS

23.2 in

13.2 in.

24.4 in.

100 lbs.

589 mm

336 mm

620 mm

46 kg

SORTIE

DUTY CYCLE

AMPS

VOLTS AT RATED AMPS

60% Duty Cycle

225

29

100% Duty Cycle

200

28

REGISTRE DE COURANT

TENSION DE CIRCUIT OUVERT

PUISSANCE AUXILIAIRE

Courant de Crête

1

0 - 450 Amps

85 VDC Maximum

115

2

VAC @ 4 Amps

Courant de Fond 0 - 125 Amps

42 VAC @ 4 Amps

1

À des tensions dʼentrée faibles (inférieures à 208 VAC) et à des tensions dʼentrée de 380 VAC à 415 VAC, il peut y avoir une réduction de

15% du Courant de Crête.

2

115 VAC inexistant sur les modèles européens.

DIMENSIONS PHYSIQUES