Set receive to transmit delay, Report number of floats, Report receive to transmit delay – VEGA VEGABAR 83 Modbus and Levelmaster protocol - Operating Instructions Manuel d'utilisation
Page 79

79
10 Annexe
VEGABAR 83 • Protocole Modbus et Levelmaster
46295-FR-131120
Response:
Paramètres
Length
Code/Data
Set Baud Rate
11 characters ASCII
Exemple : U01B9600E71
Modifier l'appareil à l'adresse 1 en vitesse de transmission 9600, parité paire, 7 bits de données, 1
bit d'arrêt
Set Receive to Transmit Delay
Request:
Paramètres
Length
Code/Data
Set Receive to Transmit Delay
7 characters ASCII
UuuRmmm
mmm = milliseconds (50 up to 250),
default = 127 ms
Response:
Paramètres
Length
Code/Data
Set Receive to Transmit Delay
6 characters ASCII
UuuROK
Report Number of Floats
Request:
Paramètres
Length
Code/Data
Set Receive to Transmit Delay
4 characters ASCII
UuuF
Response:
Paramètres
Length
Code/Data
Set Receive to Transmit Delay
5 characters ASCII
UuuFn
n = number of measurement values
(0, 1 or 2)
Report Receive to Transmit Delay
Request:
Paramètres
Length
Code/Data
Report Receive to Transmit Delay
4 characters ASCII
UuuR
Response:
Paramètres
Length
Code/Data
Report Receive to Transmit Delay
7 characters ASCII
UuuRmmm
mmm = milliseconds (50 up to 250),
default = 127 ms