Installer checklist, Final check list, Gas supply – Thermador PRD36 Manuel d'utilisation
Page 30: Electrical

Page 27
•
Adjust the shutter to more-closed position if the flame is lifting or blowing, or is
not carrying over.
•
Adjust the shutter to more-open position if the flame is too yellow. (See
Figure 17.)
•
Retighten the shutter screw(s).
•
After adjustment, reinstall the burner and perform flame evaluation. The air
shutter must fit over the orifice hood for proper operation of the burner.
•
Repeat procedure as needed until flame characteristics are acceptable. (See
Figure 16).
WARNING
Burner adjustments must be performed by a qualified technician.
Improper adjustments may cause harmful by-products or void the appli-
ance's warranty.
Allow burners to cool before attempting to remove them!
Call Thermador® if:
1. Any of the burners do not light.
2. Any of the burners continue to burn yellow.
Installer Checklist
Final Check List
•
Specified clearances maintained to cabinet surfaces.
•
Unit Level – front to back – side to side.
•
Burner caps positioned properly on burner bases.
•
All packaging material removed.
•
Island trim or backguard attached according to instructions.
•
Kick panel in place and two (2) screws secure.
•
The griddle or grill plate and frame is correctly positioned, tilted slightly forward.
(See Page 12 for adjustment procedure.)
Gas Supply
•
Manual gas shut off valve installed in an accessible location (without requiring
removal of range).
•
Unit tested and free of gas leaks.
•
If used on propane gas, verify that the propane gas supply is equipped with its
own high pressure regulator in addition to the pressure regulator supplied with
the appliance.
Electrical
•
Receptacle with correct over-current protection is provided for service cord con-
nection.
•
Proper ground connection.
Figure 17: Air Shutter Adjustment (if necessary)
Air
Shutter
Screw
More Open:
Less Yellow Flame
More Closed:
Less Blue Flame
More Carryover
Less Lifting or Blowing