Mounting anti-tip bracket – Thermador PRD36 Manuel d'utilisation
Page 17

Page 14
•
Use appropriate anchors when fastening the mounting bracket to any material
other than hard-wood or metal.
•
Prepare holes at fastener locations as identified below:
•
For walls, wall studs, or floors composed of solid wood or metal, drill 1/8"
pilot holes.
•
For walls or floors composed of drywall, sheet-rock or other soft materials,
drill 3/16" holes to a minimum depth of 1-3/4", then tap plastic anchors into
each of the holes using a hammer.
•
For walls or floors composed of concrete or concrete block, drill 3/16" holes
to a minimum depth of 1-3/4", then tap concrete anchors into each of the
holes using a hammer.
•
For walls or floors having ceramic tile covering, drill 3/16" holes through the
tile only, then drill into the material behind the tile as indicated immediately
above.
•
If the range is moved to a new location, the Anti-Tip Device must be removed
and reinstalled.
Mounting Anti-Tip Bracket
The alternative floor mounted bracket shall be installed as follows:
1. Place bracket on floor in position shown in Figure 7 (Bracket may be used in
either corner of the installation area).
2. Secure to floor or wall stud.
3. Later, when the unit is installed, the adjustable leg will slide under the bracket.
Figure 6: Mounting Anti-tip Bracket
Figure 7: Placement of Anti-Tip Bracket (Top View)
4-7/8"
from edge of range
4-7/8"
typical -
either side)
Wall Line
Floor
Right
Cabinet
Front Edge of
Right Cabinet
Left
Cabinet