2 clearences from the boiler – Rinnai Q130SN Manuel d'utilisation
Page 15

Installation & Servicing Instructions Rinnai Q-Series
15
Minimum required clearances
to combustibles
Minimum required clearances
to non-combustibles
Recommended
service clearances
All types
A
ll types
A
ll types
inch / mm
inch / mm
inch / mm
Top of boiler
2" / 50
2" / 50
10" / 250
Back of boiler
0"
0"
0
Front of boiler
6" / 150
6" / 150
24" / 600
Left side of boiler
2" / 50
2" / 50
2" / 50
Right side of boiler
2" / 50
2" / 50
2" / 50
Floor / Ground
12" / 300
12" / 300
30" / 762
Vent
0"
0"
0"
clearances to the boiler
table 3
wall
2"
50
ceiling
Min. 10" /
250mm
15.7"
400
24"
600
service clearances to the boiler
figure 5
For closet installation: clearance is 1” / 25mm from the front.
Low Loss Header
Clearances to combustible and non-combustible is 0 inch for sides, top, front and floor/ground
5.3.2
Clearences from the boiler
2"
50