Troubleshooting and repair – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation
Page 235
Advertising

This is the typical auxiliary output volt-
age generated from a properly operat-
ing machine. Note that each vertical
division represents 50 volts and that
each horizontal division represents 5
milliseconds in time.
Note: Scope probes connected at
machine 115VAC receptacle.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VAC SUPPLY)
HIGH IDLE – NO LOAD
TROUBLESHOOTING AND REPAIR
F-47
F-47
VANTAGE® 500
15.8 ms
0 volts
50V
5ms