Test table f.2, Diode test rectifier terminal connections, Troubleshooting and repair – Lincoln Electric VANTAGE SVM178-B Manuel d'utilisation
Page 229: Output rectifier bridge test (continued)
Advertising

OUTPUT RECTIFIER BRIDGE TEST(CONTINUED)
TROUBLESHOOTING AND REPAIR
F-41
F-41
VANTAGE® 500
TABLE F.2 – DIODE TEST TABLE
AC1
DC(+)
Forward Bias
(Low Resistance)
AC2
DC(+)
Forward Bias
(Low Resistance)
AC3
DC(+)
Forward Bias
(Low Resistance)
DC(-)
AC1
Forward Bias
(Low Resistance)
DC(-)
AC2
Forward Bias
(Low Resistance)
DC(-)
AC3
Forward Bias
(Low Resistance)
AC1
DC(-)
ReverseBias
(High Resistance)
AC2
DC(-)
ReverseBias
(High Resistance)
AC3
DC(-)
ReverseBias
(High Resistance)
DC(+)
AC1
ReverseBias
(High Resistance)
DC(+)
AC2
ReverseBias
(High Resistance)
DC(+)
AC3
ReverseBias
(High Resistance)
DIODE TEST
RECTIFIER
TERMINAL
CONNECTIONS
TEST INSTRUMENT
(+) Lead
(-) Lead
DIODE BIAS
& EXPECTED
TEST RESULT
18. Reconnect all leads.
19. Perform the Case Cover Replacement Procedure.
Advertising