General maintenance, Daily maintenance, Hour maintenance – Shindaiwa PowerBroom 80732 Manuel d'utilisation

Page 13

Advertising
background image

13

ENGLISH

IMPORTANT!

MAINTENANCE, REPLACEMENT OR
REPAIR OF EMISSION CONTROL
DEVICES AND SYSTEMS MAY BE
PERFORMED BY ANY REPAIR ESTAB-
LISHMENT OR INDIVIDUAL; HOW-
EVER, WARRANTY REPAIRS MUST BE
PERFORMED BY A DEALER OR
SERVICE CENTER AUTHORIZED BY
SHINDAIWA KOGYO CO., LTD. THE
USE OF PARTS THAT ARE NOT
EQUIVALENT IN PERFORMANCE AND
DURABILITY TO AUTHORIZED PARTS
MAY IMPAIR THE EFFECTIVENESS
OF THE EMISSION CONTROL SYSTEM
AND MAY HAVE A BEARING ON THE
OUTCOME OF A WARRANTY CLAIM.

Muffler

This unit must never be operated with a
faulty or missing spark arrester or muffler.
Make sure the muffler is well secured and
in good condition. A worn or damaged
muffler is a fire hazard and may also cause
hearing loss.

Spark Plug

Keep the spark plug and wire connec-
tions tight and clean.

Fasteners

Make sure nuts, bolts, and screws
(except carburetor adjusting screws) are
tight.

Prior to each work day, perform the
following:
■ Remove all dirt and debris from the

engine, check the cooling fins and air
cleaner for clogging, and clean as
necessary.

■ Carefully remove any accumulations of

dirt or debris from the muffler and fuel
tank. Dirt build-up in these areas can
lead to engine overheating, fire, or
premature wear.

General Maintenance

WARNING!

Before performing any maintenance,
repair or cleaning work on the unit,
make sure the engine and sweeper
belts are completely stopped. Discon-
nect the spark plug wire before
performing service or maintnenance
work.

WARNING!

Non-standard parts may not operate
properly with your unit and may
cause damage and lead to personal
injury.

Daily Maintenance

■ Check for loose or missing screws or

components. Make sure the sweeper
drums are securely fastened.

■ Check the entire unit for leaking fuel

or grease.

10-Hour Maintenance

PB2500.17

Unscrew

Fastener

Remove and clean

or replace

the element

Every 10 hours of operation (more
frequently in dusty or dirty conditions):
Remove the air cleaner element.
See Figure 25. Clean or replace as
necessary. To clean element: wash it
thoroughly in soap and water. Let it
dry before reinstalling the element.

CAUTION!

Do not operate the unit if the air
cleaner or element is damaged, or if
the element is wet.

Figure 25

Advertising
Ce manuel est liée aux produits suivants: