High frequency intensity control, Power switch and pilot light, Postflow timer – Miller Electric HF-251D-1 Manuel d'utilisation
Page 20: Shielding gas, 4. high frequency intensity control, 5. power switch and pilot light, 6. postflow timer, 7. shielding gas
Advertising

OM-611 Page 16
1
High Frequency Intensity
Control
Use control to change amount of
HF energy used to start and/or
maintain the arc. Set as low as
practical to prevent interfering with
electronic equipment.
1
4-4.
High Frequency Intensity Control
1
Power Switch
Use switch to turn unit On and Off.
2
Pilot Light
1
2
4-5.
Power Switch And Pilot Light
Postflow Timer
A fixed 15 second Postflow Timer
controls the period of time shielding
gas flows after the arc is extin-
guished.
t
2
4-6.
Postflow Timer
1
Shielding Gas Cylinder
2
Valve
3
Hand Control
4
Foot Control
Open valve on cylinder just before
welding.
Control turns weld output and gas
flow on and off.
Close valve on cylinder when fin-
ished welding.
sb5.2* 5/94 − S-0621-C / S-0769 / Ref. 159 059
2
1
4
OR
3
4-7.
Shielding Gas