Power source plug information and connections, 4. power source plug information and connections – Miller Electric HF-251D-1 Manuel d'utilisation
Page 15

OM-611 Page 11
The supplied cord with plugs is for use with CC or CC/CV welding power sources
having the proper, matching 14-pin receptacle. Do not use cordset on machines
without the 14-pin receptacle.
NOTE
159 645-A / Ref. S-0004-A / S-0283-A
Y
Turn Off HF Unit and welding
power source, and discon-
nect input power before
making connections. Stop
engine on welding genera-
tors.
1
Six-Pin Power Source Block
Plug PLG2
2
Supplied Six-Pin Receptacle
RC2
3
Strain Relief Clamp
4
Remote 14 Plug PLG4
5
Keyway
To Connect PLG4 to Remote 14 re-
ceptacle on the welding power
source, align keyway, insert plug
and tighten threaded collar.
Connect Remote 14 Plug PLG4 if remote
contactor and/or remote amperage control
from the HF unit are desired.
A
J
B
K
I
C
L
N
H
D
M
G
E
F
5
4
3
2
1
2
1
6
5
4
3
The following pin information is included
in case the supplied cord is not suitable,
and it is necessary to wire a receptacle
to interface with plug PLG2.
Front View
Of PLG2
Pin*
Pin Informaton
Remote
Contactor Control
Remote
Amperage Control
1, 2
*The remaining pin is not used.
3
4
5
Provides contact closure for Output (Contactor) operation.
Amperage control connection − maximum side.
Amperage control connection − wiper contact.
Amperage control connection − minimum side.
3-4.
Power Source Plug Information And Connections