6. INTERNAL BLOWERS Internal blower downdrafts are

shipped from the factory ready to vent in the down position.

If you need to vent back, left or right, then the blower must

be repositioned.

TO VENT TO THE LEFT OR THE RIGHT

Four hex nuts attach the blower box to the downdraft body.

Remove all four nuts and carefully remove the blower box.

To vent left or right, simply rotate the blower box 90° to the

left or right and re-assemble.

TO VENT TO THE REAR

Venting to the rear requires that the blower be repositioned

inside the blower box as indicated in FIGURE 9. The blower

is attached to the blower box by 6 screws. Remove the blower

from the blower box. Note the position of the angle mounting

rails on each side of the blower. To vent to the rear, both

mounting rails must be repositioned on the blower as illus-

trated in FIGURE 10. Attach the mounting rails as indicated.

Re-attach the blower to the blower box.

When attaching the Under Counter Mounting Brackets:

• DO NOT drill into the countertop surface.

• Check that the mounting screws are proper length and

will not extend through the countertop surface when

tightened.

Failure to follow these warnings could result in damage to

the countertop surface.

FIGURE 9

FIGURE 11

FIGURE 10

Re-attach the blower box to the downdraft. The square metal

frame must be attached to the mouth of the blower. The

exhaust knockout on the rear must be removed. A metal

plate and two screws are supplied in the hardware package

to cover the unused exhaust exit.

CAUTION: Make sure that the wiring cable connecting the

blower to the field wiring compartment remains securely at-

tached under the two cable clamps.

7. Attach the Backdraft Damper.

8. Remove the field wiring compartment cover and deter-

mine which direction the wiring will run from the appliance to

the wiring box and remove the wiring knockout.

9. Insert the downdraft unit into the countertop cutout.

Make sure that the unit is firmly placed at the rear of the cut-

out. Fasten the legs to the cabinet floor using the two longer

Phillips head screws supplied in the hardware package.
10. Attach the downdraft to the countertop using the Un-

dercounter Mounting Brackets (FIGURE 8). This system is

designed to adjust to different countertop thicknesses. Using

the small Phillips head machine screws in the hardware pack-

age, attach one Undercounter Mounting Bracket to the slot

on the upper right corner of the unit. Attach the other end of

the Bracket to the underside of the countertop.
11. Thread the power supply cable through the wiring

knockout into the field wiring compartment. Connect the

three White wires together with a twist-on wire connector.

Connect the two Black wires with a twist-on wire connector.

Attach the Green ( or Green and Yellow) ground wire to the

eyelet with the green grounding screw. Replace the field

wiring compartment cover.

Venting Left, Right or Down

Venting to the Rear

REMOTE BLOWERS The remote blower must be con-

nected to the downdraft by a separate wiring cable which

is not supplied with the downdraft. A separate wiring

knockout is supplied for the remote blower as indicated

in FIGURE 11. THE REMOTE BLOWER MUST NOT BE

WIRED INTO THE WIRING BOX.

WIRING

KNOCKOUT

FOR

CONNECTING

THE REMOTE

BLOWER

WIRING BOX

FOR POWER

SUPPLY

TO THE

DOWNDRAFT.

DO NOT WIRE

THE REMOTE

BLOWER

CABLE INTO

THIS WIRING

BOX.

12. Remove the wiring knockout for the remote blower

and install conduit connector. Feed remote blower wiring

through conduit connector. DO NOT WIRE THE REMOTE

BLOWER BLACK AND WHITE WIRES INTO THE WIR-

ING BOX. WIRES MUST BE CONNECTED AS SHOWN

ABOVE. Connect the white wires together with a twist-on

wire connector. Connect the black wires together with a

twist-on wire connector. Attach ground wire to eyelet with

green ground screw and tighten screw. Tighten conduit

connector clamp screws.

WARNING

!

13. Turn the power supply on. Push and hold the Up/Down

button momentarily. The downdraft will rise out of the countertop

and stop in the fully extended position. Position the top strip

over the the top of the downdraft, lining up the fixing hooks

and the hole for the push button. Snap into place. Turn the

blower on. The blower control switch is located on the right

hand side of the plenum as indicated in FIGURE 12.
IF THE BLOWER DOES NOT OPERATE: (1) Check that

the circuit breaker is not tripped or the house fuse blown. (

2) Check that the grease filters are properly installed. ( See

the section on Safety Microswitches ), (3) Disconnect the

power supply and check that the wiring connections have

been made properly.
14. Connect the ductwork to the Backdraft damper. Seal

all joints with duct tape and vent to the outside of the home.
15. Install the cooktop according to the cooktop manufac-

turer's instructions. Check to make sure that the rear edge of

the cooktop overlaps the front edge of the downdraft by 3/8".