Faber Scirocco Downdraft Rangehood Manuel d'utilisation

Page 4

Advertising
background image

Version 5/07 - Page 4

9 Feet Straight Duct

2 - 90˚ Elbows

Wall Cap

Total System

9.0 feet

14.0 feet

0.0 feet

23.0 feet

FIGURE 4

5.0 feet

7.0 feet

12.0 feet

0.0 feet

45˚ Elbow

90˚ Elbow

90˚ Flat Elbow

Wall Cap

FIGURE 3

FIGURE 2

REMOTE BLOWER DUCTING

FIGURE 1

VENTING DOWN

VENTING LEFT

VENTING RIGHT

VENTING BACK

INTERNAL BLOWER DUCTING

TOOLS NEEDED FOR INSTALLATION

• Saber Saw or Jig Saw

• Drill

• 1 1/4" Wood Drill Bit

• Pliers

• Phillips Screwdriver

• Flat Blade Screwdriver

• Wire Stripper or Utility Knife

• Metal Snips

• Measuring Tape or Ruler

• Level

• Pencil

• Caulking Gun

• Duct Tape

PARTS SUPPLIED FOR INSTALLATION

• 6 Mounting Brackets

• 2 End Caps

• 16 Screws

• 1 Literature Package

• 1 Backdraft Damper - Internal Blower Model Only

PARTS NEEDED FOR INSTALLATION

• 2 Conduit Connectors

• Power Supply Cable

• Wiring Cable - Optional Remote Blower Only

• 1 Wall or Roof Cap

• All Metal Ductwork

OPTIONAL ACCESSORIES AVAILABLE

• Remote Blower

for remote blower downdrafts only, model# 630001732

• Trim Kits

to replace the stainless steel top trim with a black or white trim

PLAN THE DUCTWORK

The Scirocco downdraft system is designed to offer wide flex-

ibility in ducting. The interior blower can be ducted in four

different directions; down, left, right or back using a 3 1/4"

X 10" rectangular vent. The remote blower can be ducted

in three directions; down, left or right using a 10" round vent.

FIGURES 1 and 2 illustrate venting options.

The remote blower requires a separate wiring cable that should

be installed at the same time that the ductwork is installed. For

best results, 10" duct is recommended for the remote blower.

A damper plate is included in the box with the remote blower

and must be attached over the opening of the front of the

downdraft blower box. Remote blower can be mounted on

either an outside wall or the roof of the home.

FIGURE 5 shows the ductwork cutout dimensions for the

internal blower model only. The remote blower connects us-

ing a 10" round duct. The location of the cutout for this duct

will depend upon your specific installation.

FIGURE 5

CALCULATE THE DUCTRUN LENGTH

The ductwork length should not exceed 35 equivalent feet for 3

1/4" X 10" duct, or 55 equivalent feet for 9" or 10" round duct.

Calculate the length of the ductwork by adding the equivalent

feet listed in FIGURE 3 for each piece of duct in the complete

system. An example is given in FIGURE 4.

For best results, use no more than three 90° elbows. Make

sure that there is a minimum of 24" of straight duct between

elbows if more than one is used. Do not install two elbows

together. Round duct is recommended instead of rectangular

duct especially if elbows are needed. For internal blower

models, rectangular duct should be transitioned to 6" round

as soon as possible.

30 White part# 6096090

36 White part# 6096091

30 Black part# 6096092

36 Black part# 6096093