Operation, Manual mode – Heath Zenith Carriage Light with Motion-activated Sensor 52-4477-8 Manuel d'utilisation

Page 5

Advertising
background image

5

598-1285-00

0 ft.

(9.1 m)

6 ft.

(1.8 m)

150°

3. Walk through the coverage area noting where

you are when the lights turn on. In TEST mode,

light will stay on for 5 seconds after sensing

motion and then turn off.

4. Move the sensor head left or right to change

the coverage area. Note: Grasp the sensor only

as shown and turn the entire sensor. any other

method may damage the sensor. Do not

force it past the stops.

Maximum Range

Maximum

Coverage Angle*

(Top View)

Note:

When first turned on wait about 1

1

/

2

minutes

for the circuitry to calibrate.

* resets to Auto Mode at dawn.

Least Sensitive

Most Sensitive

The sensor is less sensitive to motion directly

towards it and more sensitive to motion across

coverage area.

Sensor

Motion

OPeratiOn

Mode:

On-Time

Works: Day Night

test

5 Seconds

x

x

auto

1, 5, or 10

Minutes

x

Manual

To Dawn*

x

... back on.

1 Second

OFF then...

Manual mode only works at

night because daylight returns

the sensor to AUTO.
Flip the light switch off for one

second then back on to toggle

between AUTO and MANUAL

MODE.
Manual mode works only with

the ON-TIME switch in the 1,

5, or 10 position.

ManuaL MODe

240°

Sensor

Aiming

Adjustment

Angle

5. Adjust the SENSITIVITY to increase or

decrease the range as needed. Too much sen-

sitivity may cause false triggering due to heat

sources in the coverage area (see Adjustment of

Coverage Area or Troubleshooting section).

6. Set the amount of ON-TIME you want the

light to stay on after motion is detected (1, 5,

or 10 minutes).

Motion

Advertising