Venting venting, Venting the dryer, Vent health – GE Profile 27 Inch Electric Dryer Owners Guide Manuel d'utilisation

Page 12

Advertising
background image

12

49-3000244 Rev 3

VENTING

Venting

Venting the Dryer

For the best drying performance, the dryer needs to be properly vented. The dryer will use more energy and run longer if it is
not vented to the specifications below. Carefully follow the details on Exhausting in the Installation Instructions.

„

Use only rigid metal 4” diameter ductwork inside the dryer cabinet. Use only rigid

metal or UL listed flexible metal 4” diameter ductwork for exhausting to the outside.

„

Do not use plastic or other combustible ductwork.

„

Use the shortest length possible.

„

Do not crush or collapse.

„

Avoid resting the duct on sharp objects.

„

Venting must conform to local building codes.

This dryer MUST be exhausted to the outdoors.
Use only 4” rigid metal ducting for the home exhaust duct.
Use only 4” rigid metal or UL-listed dryer transition duct to connect the dryer to the home exhaust.

DO NOT

use a plastic vent.

DO NOT

exhaust into a chimney, kitchen exhaust, gas vent, wall, ceiling, attic, crawl space, or

concealed space of a building.

DO NOT

install a screen in or over the exhaust duct.

DO NOT

install a booster fan in the exhaust duct.

DO NOT

use duct longer than specified in the exhaust length table.

Failure to follow these instructions can result in death or fire.

WARNING

- Fire Hazard

Correct

Venting

Incorrect

Venting

Vent Health

Is a diagnostic test to verify the status of the venting system.

NOTE:

To run the test, ambient temperature must be

below 85°F (if temperature is above 85°F the test will be invalid and the main display will show “00”).

NOTE:

On some models this features is only available through the GE Appliances SmartHQ App.

To enter Vent Health test mode:

1

Ensure the drum is empty.

2

Ensure the lint filter is clean.

3

Press and hold the

Time

and

Level

buttons for 3 seconds.

4

Close the door and press

Start

.

After the test is run, the display will show a number. Use the table below to understand the result and the action needed.

Main Display

LED Display

Result

Action*

01

OFF

Clean/Normal

Your house vent is in good condition

and no action is required.

02

OFF

May need attention

Your house vent condition may affect your

dryer’s performance. Check and clean

or make adjustments to improve.

03

Vent Blocked

Blocked

Your house vent is highly restricted and

is affecting your dryer’s performance.

Clean and/or make needed

adjustments to improve.

*

Also see

Interior and Duct

in the

Care and Cleaning

section.

Advertising