Model #170favt wiring diagram, 170favt - wiring chart, How much heat do i require – Enerco MR. HEATER MH170FAVT Manuel d'utilisation
Page 6: Recommended minimum gauge for cord extensions, Btu's per hour required, Warning, Color code

Enerco Group, Inc. | Force-Air Propane Construction Heater
Operating Instructions and Owner’s Manual
70176 Rev. C 4/07
6
HIGH-LIMIT SWITCH X2
LINE
VALVE
NEUT
GRD
CHASSIS
GROUND
CHASSIS
GROUND
CHASSIS
GROUND
CHASSIS
GROUND
CHASSIS
GROUND
LINE CORD
THERMOSTAT
MOTOR
GAS
VALVE
FLAME CONTROL
SPARK PLUG
G
W
G
G
B
B
B
B
R
W
W
R
Y
B
Y
G
G
CP MARK 10DN
Model #170FAVT
WIRING DIAGRAM
If any original wiring as supplied by the heater must be
replaced, it must be replaced with type AWG 105° C
wire or its equivalent except as indicated
(*type SF2-200, **SGI 250° C).
170FAVT - WIRING CHART
COLOR
LENGTH
FROM
TO
White
7 "
V a l v e
Terminal Block
Black
6"
On/Off Switch
Terminal Block
Yellow - (Hi-Temp) 16 1/2"
High Limit Switch
Valve
Yellow - (Hi-Temp) 16 1/2"
High Limit Switch
Terminal Block
Orange
11"
Flame Control
Spark Plug
(Ignition)
Green
7 "
Flame Control
Ground
( H a r n e s s )
R e d
7 "
Flame Control
Terminal Block
( H a r n e s s )
White
6 "
Flame Control
Terminal Block
( H a r n e s s )
Black
6 "
Flame Control
Terminal Block
( H a r n e s s )
HOW MUCH HEAT DO I REQUIRE?
For economy, it is important to match input to that
required. But heat requirements often vary. For
example, it usually takes a lot more heat to get things
warm than it does to keep them that way. Likewise,
outside air temperature ususally changes during the day
so you may need more heat at night than you do in the
daytime. An approximation of the heat required can be
found by using the chart below.
Recommended Minimum Gauge
for Cord Extensions
Wire Gauge Chart A.W.G.
Name
Plate 120V
Cord Length in Feet
Amps.
25
50
100
150
5-6
18
16
14
12
6-8
18
16
12
10
8-12
18
14
12
10
10-12
16
14
10
8
12-14
16
12
10
8
WARNING:
When using a thermostat controled heater,
its exit area should be protected from personnel and
warnings posted of sudden startup.
Cubic feet
Temperature Rise Required (
o
F)*
of space to
be heated
20
o
30
o
40
o
50
o
5,000
14,000
20,000
27,999
34,000
7,000
19,000
28,000
38,000
47,000
10,000
27,000
40,000
54,000
67,000
15,000
40,000
60,000
80,000 100,000
20,000
54,000
80,000 107,000 133,000
30.000
80,000 120,000 160,000 200,000
50,000 133,000 200,000 266,000 333,000
BTU'S PER HOUR REQUIRED
COLOR CODE
B - BLACK
R - RED
L - BLUE
W - WHITE
G - GREEN
O - ORANGE