Service procedures – Desa BC40 Manuel d'utilisation

Page 14

Advertising
background image

www.desatech.com

111168-01A

14

PUMP ROTOR

(Procedure if Rotor is Binding)
1. Remove upper shell (see Upper Shell Re-

moval, page 9).

2. Remove filter end cover screws using 5/16"

nut-driver (see Figure 25 or 26).

3. Remove filter end cover and air filters.
4. Remove pump plate screws using 5/16" nut-

driver.

5. Remove pump plate.
6. Remove rotor, insert, and blades.
7. Check for debris in pump. If debris is found,

blow out with compressed air.

8. Install insert and rotor.
9. Check gap on rotor. Adjust to .003"/.004"

(.076-.101 mm) if needed (see Figure 27).

Note:

Rotate Rotor one full turn to insure the gap

is .003"/.004" (.076-.101 mm) at tightest position.

Adjust if needed.
10. Install blades, pump plate, air filters, and filter

end cover.

11. Replace fan guard and upper shell (see Upper

Shell Removal, page 9).

12. Adjust pump pressure (see Pump Pressure

Adjustment, page 10).

Note:

If rotor is still binding, proceed as follows.

13. Perform steps 1 thru 6.
14. Place fine grade sandpaper (600 grit) on flat

surface. Sand rotor lightly in “figure 8” motion

four times (see Figure 28).

15. Reinstall insert and rotor.
16. Perform steps 10 thru 12.

Figure 26 - Rotor Location, 115T/165T

Models

Figure 25 - Rotor Location, 40/55T/70T

Models

Rotor

Air Output
Filter

Insert

Fan Guard

Filter End
Cover

Air Intake Filter

Blade

Pump Plate

Insert

Rotor

Air Output
Filter

Blade

Filter End Cover

Air Intake Filter

Pump Plate

Fan Guard

Gap Adjusting Screw

Rotor

Blade

.003"/.004"
(.076-.101 mm)
Gap Measured
With Feeler
Gauge

Gap Adjusting Screw

Figure 27 - Gap Adjusting Screw

Locations

Sandpaper

Figure 28 - Sanding Rotor

SERVICE PROCEDURES

Continued

Advertising
Ce manuel est liée aux produits suivants: