9

DIRECT DRAIN INSTRUCTIONS

DIRECT DRAIN

FEATURE

This dehumidifier is inclusive of a direct drain feature, located at the rear

of the cabinet. NOTE: The drain hose is not included with the unit. The

direct drain feature is intended for use in basements inclusive of a floor

drain only.

NOTE: Do not attempt to operate the direct drain

feature using drain/stem pipes above ground level.

CONNECTING THE DIRECT DRAIN:

1) Remove (cut away) drain cover located at the rear of

the unit (see Fig. 3) and remove the water tank located

at the front of the unit.

2) Cut drain hose to required length (to suit your needs).

You do not need any fittings on either end of the drain

hose. Insert one end of garden hose directly into drain

opening (see Fig. 4).

3) Push firmly onto the drain connector until it stops (see

Fig. 5). NOTE: This connection requires a pressure fit

application only. Make sure the hose is seated all the

way back on the drain connection nipple.

4) Re-install the water tank, making sure the water full

light turns “off”. If the light remains on, the tank has not

been properly installed. The water tank must always be

installed inside the cabinet whenever the direct drain

option is being used.

5) Position the dehumidifier as close as you can to the

floor drain.

6) Position the open end of the drain hose directly over

the floor drain and start the unit.

7) When the direct drain feature is not being used,

remove the drain hose from the direct drain nippe and

plug the Direct Drain opening (Fig. 3) with the rubber

cap provided.

Fig. 3

Fig. 4

Fig. 5