RANGE HOOD CARE

Cleaning

IMPORTANT: Clean the hood and grease filters frequently

according to the following instructions. Replace grease

filters before operating hood.

Exterior Surfaces:

To avoid damage to the exterior surface, do not use steel wool

or soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:

Liquid detergent soap and water, or all-purpose cleanser

Wipe with damp soft cloth or nonabrasive sponge,

and then rinse with clean water and wipe dry.

Metal Grease Filter:

1. Remove the filter by pulling the spring release handle

and then pulling down the filter.

2. Wash metal filter as needed in dishwasher or hot

detergent solution.

3. Reinstall the filter by making sure the spring release handles

are toward the front. Insert aluminum filter into upper track.

4. Push in spring release handle.
5. Push up on metal filter and release handle to latch into place.

Non-Vented (recirculating) Installation Filters:

The charcoal filter is not washable. It should last up to

6 months with normal use. Replace with Charcoal Filter

Kit Number W10412939.
To replace charcoal filter:
1.
Remove metal grease filter from range hood.

See “Metal Grease Filter” in this section.

2. Bend spring clips away from metal grease filter.

3. Place charcoal filter into top side of metal filter.

4. Bend spring clips back into place to secure the

charcoal filter to the metal filter.

5. Replace metal grease filter. See “Metal Grease Filter”

in this section.

Replacing a Lamp

Turn off the range hood and allow the lamp to cool. To avoid

damage or decreasing the life of the new bulb, do not touch

bulb with bare fingers. Replace bulb using tissue or wearing

cotton gloves to handle bulb.
If new lamps do not operate, make sure the lamps are inserted

correctly before calling service.
1. Disconnect power.
2. Use a Phillips screwdriver to remove screw from lamp cover.

3. Remove lamp cover and set lamp cover and the screw aside.

4. Remove bulb and replace with a new 120 volt, 40 watt

maximum E-12 bulb.

5. Replace lamp cover and reinstall screw.
6. Reconnect power.

A

A. Spring release handle