anti-tip block

NorMal INSTallaTIoN STepS

ANTI-TIP BLOCK INSTALLATION INSTRUCTIONS
To reduce the risk of tipping of the drawer, the Anti-Tip

block must be properly installed located 14 ³₄" above

the floor on which the Microwave In-A-Drawer™ will sit.

The 6" Anti-Tip block must be provided by the installer.

See Figures 2 and 6 for (24") or Figures 4, 5, and 6

(for 30"). The Anti-Tip block prevents serious injury that

might result from spilled hot liquids.
If the drawer is ever moved to a different location, the

Anti-Tip block must also be moved and installed. When

installed to the wall, make sure that the screws completely

penetrate the dry wall and are secured in wood or metal

Design Specifications

Verifying package Contents

Remove all packing materials from inside the drawer.

DO NOT REMOVE THE WAVEGUIDE COVER, which is

located on the top of the Microwave In-A-Drawer™.

Waveguide
Cover

Sealing
Surface

Remove the feature sticker, if there is one. Check

the drawer for any damage, such as misaligned or

bent drawer, damaged drawer seals and sealing

surfaces, broken or loose drawer guides and

dents inside the cavity or on the front side of the

drawer. If there is any damage, do not operate

the Microwave In-A-Drawer™ and contact your

dealer or a DACOR AUTHORIZED SERVICER.

Sealing
Surface

Oven
Cavity

Figure 7

electrical outlet

4"

5"

electrical outlet location

2x4 Anti-

Tip block

(6")

Figure 8

The electrical requirements are a 120 volt 60 Hz, AC

only, 15 amp. or more protected electrical supply.

It is recommended that a separate circuit serving

only this appliance be provided.
The drawer is equipped with a 3-prong grounding

plug. It must be plugged into a wall receptacle that

is properly installed and grounded. Should you only

have a 2-prong outlet, have a qualified electrician

install a correct wall receptacle.
NOTE:
If you have any questions about the grounding or

electrical instructions, consult a qualified electrician

or service person.

so that the block is totally stable. When fastening, be

sure that the screws do not penetrate electrical wiring

or plumbing.

4"

5"

electrical outlet location

Anti-Tip

block

(6")

Figure 6

Installation Instructions