Accessories, Troubleshooting – Desa RCCP80V Manuel d'utilisation

Page 7

Advertising
background image

104781-01D

7

7

For more information, visit www.desatech.com

For more information, visit www.desatech.com

WARNING: Never attempt to service heater while it is connected to

propane supply, operating, or hot. Severe burns can occur.

SYMPTOM

Burner fails to light

Burner lights but goes out when automatic
control valve button is released

Burn rate is low

POSSIBLE CAUSE

1. Propane supply valve closed on propane

tank(s)

2. Excess-flow check valve closed

4. Blockage in burner orifice
5. Piezo ignition system not sparking

1. Not enough warm-up time

2. Low gas pressure

3. Thermocouple loose or needs to be

replaced

4. Automatic control valve needs to be

replaced

1. Main burner valve not fully open

2. Plugged gas orifices
3. Low gas pressure
4. Low fuel supply

REMEDY

1. Open propane supply valve slowly

2. Close propane supply valve on propane

tank and reopen slowly

4. Replace burner orifice
5. Assure ignitor electrode gap is 5.0 mm

(.195 in). Check wire lead for damage
Replace piezo ignitor and/or ignitor elec-
trode as necessary. Do not bend elec-
trode, this may cause breakage

1. Relight, hold automatic control valve

button in 45 seconds

2. Check propane tank(s) for proper gas

supply

3. Tighten connection or replace ther-

mocouple

4. Replace automatic control valve

1. Fully open main burner valve by push-

ing in control knob and turning counter-
clockwise towards HIGH position until
it stops

2. Replace gas orifice
3. Check gas supply; check regulator output
4. Consult propane gas supplier

ACCESSORIES

Purchase accessories and parts from your nearest dealer or service
center. If your dealer or service center can not supply an accessory
or part, call DESA Industries' at 1-905-826-8010. You can also
write to the address listed on the back page of this manual.

DESA Industries
2220 Argentia Road
Unit #4
Mississauga, ON
L5N2K7
905-826-8010

Part Number

Description

LPA4020

Fuel Gas Connector
Connects regulator to all standard propane
tanks. U.L. and AGA listed.

LPA3005

Hose/Regulator Assembly

TROUBLESHOOTING