A grounded three prong non-GFCI electrical outlet must

be provided and should be in a location that allows the

refrigerator to be connected without an extension cord. See

“Electrical Requirements” for additional information.

The plumbing for the water line can come through the floor

flush to or from the back wall. Install the water valve in a

location that allows it to be turned off without moving the

refrigerator out in the event the refrigerator or water line

requires service.

For model IF36, see document 100504 for instructions on

planning and installing integrated front panels. It is available

at www.Dacor.com.

WAtER VAlVE locAtIoN -

APPRoxIMAtE DIMENSIoNS

W

ater

S

upply

r

equirementS

All installations must meet local plumbing code

requirements.

Use 1/4” (6 mm) copper line to connect the refrigerator to

the house cold fresh water supply.

Install a shut off valve between the refrigerator and water

supply. The shut off valve should be a drilled saddle valve.

See the diagram above for recommended location.

Do not use a piecing type or 3/16” (4.76 mm) saddle valve

which will reduce water flow and clog more easily.

Allow a minimum of 24” (610 mm) diameter service loop of

copper tubing outside the wall or floor for easy connection to

the water supply.

cold water supply

Connect the ice maker to a cold water line with water pressure

between 35 and 120 psi. If you have any questions about your

water pressure, call your utility company.

i

nsTallaTion

s

PeCifiCaTions

70 ½” Min.

(1791 mm)

30”.

(762 mm)

Water Valve Location - Approximate Dimensions

24” (610 mm)

36” Min. (914 mm)

16”

(406 mm)

Reverse osmosis water supply

IMPoRtANt: The pressure of the water supply coming out of

a reverse osmosis system going to the water inlet valve of the

refrigerator needs to be between 35 and 120 psi (241 and 827

kPa).
If a reverse osmosis water filtration system is connected to your

cold water supply, the water pressure to the reverse osmosis

system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
If the water pressure to the reverse osmosis system is less than

40 to 60 psi (276 to 414 kPa):
■ Check to see whether the sediment filter in the reverse

osmosis system is blocked. Replace the filter if necessary.

Allow the storage tank on the reverse osmosis system to

refill after heavy usage.

■ If your refrigerator has a water filter, it may further reduce

the water pressure when used in conjunction with a reverse

osmosis system. Remove the water filter. See “Water

Filtration System.”

If you have questions about your water pressure, call a licensed,

qualified plumber.

e

leCTRiCal

R

equiRemenTs

A 115 Volt, 60 Hz. AC only 15 or 20 amp fused, grounded

electrical supply is required. It is recommended that a separate

circuit serving only your refrigerator be provided. Use an outlet

that cannot be turned off by a switch. Do not use an extension

cord.

ElEctRIcAl locAtIoN - APPRoxIMAtE DIMENSIoNS

12” (305 mm)

12”

(305 mm)