Gas sounding test – DCS PHFS-DW-SS Manuel d'utilisation

Page 11

Advertising
background image

10

PRECAUTIONS

• Periodically check the whole gas system for leaks

or immediately check if the smell of gas is
detected.

• Extinguish all open flames

• Never leak test while smoking. If you can not

stop a leak, turn off the cylinder valve and call
the dealer you purchased the heater from or
customer service 1-888-281-5698.

• Do not use heater until all connections have

been leak tested and do not leak.

• When leak testing, refer to the connections

diagrams below.

• Only those parts recommended by the

manufacturer should be used.

• Substitution of parts can void warranty.

LEAK TEST

Make a soap solution of one part liquid detergent, and one
part water.The soap solution can be applied with a spray
bottle, brush or rag, soap bubbles will appear where a leak
is present. Make sure the safety valve control knob is in
the “OFF” position. Turn the gas supply on check for
leaks at leak point. If a leak is present, turn off supply,
tighten any leaking fittings, turn gas on and recheck.

Gas Sounding Test

FIG.09

TEST POINTS

FIG.08

ORIFICE FITTING &
SAFETY VALVE

PILOT ASSEMBLY

&

PILOT TUBING

PILOT TUBING
TO SAFETY VALVE

5

6

7

4

INTAKE

PIPE FITTING

Advertising
Ce manuel est liée aux produits suivants: