WIRING DIAGRAM
AUX. SWITCH
LIGHT
WARMING ELEMENT
500 WATTS, 120 VAC.
GND
L1
NEU
STRAIN RELIEF
1
THERMOSTAT
TEMP. SWITCH
2
1
2
4
3
2
1
25-5/16" (WDS-27 & 30)
26-1/8" (WDI)
11-1/16" (WDS)
12-5/8" (WDI)
9-7/8" (WDS)
11-1/4"(WDI)
15-3/4"
18-3/4"
warming drawer
cutout
A)
B)
C)
D)
E)
B
double
wall oven
cutout
A
D
warming drawer
cutout**
C
B
single
wall oven
cutout
microwave
cut-out
A
E
C
**The floor of the opening should be constructed of plywood strong enough
to support the weight of the oven.
SINGLE WALL OVEN AND MICROWAVE
AND WARMING DRAWER
INSTALLATION
Fig. 10
DOUBLE WALL OVEN AND
WARMING DRAWER
INSTALLATION
INSTALLATION INSTRUCTIONS