Replacing the vibration dampers
CAUTION:
Protective gloves must be put on.
Always replace all five vibration dampers.
-
The vibration damper (
E/1
) is installed next to the
identification plate.
-
The vibration damper (
E/2
) is installed underneath the
guide bar support. The chain catch (
a
) must be removed.
-
The vibration damper (
E/5
) is installed under the mounting
arm of the tubular handle.
E
3
F
2
1
5
a
b
a
4
-
The vibration damper (
F/3
) is installed underneath the oil
tank cap.
-
The vibration damper (
F/4
) is installed underneath the pre-
filter. The cover (
a
) and pre-filter (
b
) must be removed.
STOP
-
Carefully demount the vibration damper by means of the
universal wrench.
-
The vibration damper is mounted in the reverse order.
-
Demount the tubular handle (
a
) (5 screws).
-
Use the socket wrench (accessories, not delivered with the
chain saw) to demount the vibration damper carefully.
-
The new vibration damper is mounted in the reverse order.
Replacing vibration damper 5
-
Put the saw chain on its side and carefully remove the
protective cover (
G/4
) by means of the universal wrench.
Replacing vibration dampers 1 - 4
4
G
H
a
-
Use the offset screw driver to loosen the screw inside.
I
J