Fault
Possible cause
Remedial action
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
The evaporator (refrigeration
generator) in the No Frost
system is covered in thick ice
and can no ionger be defrosted
fuiiy automaticaiiy.
To defrost the evaporator, remove
the frozen food with the
compartments, insuiate weii and
store in a cooi iocation.
Switch off the appiiance and move
it away from the waii. Leave the
appiiance door open.
After approx. 20 min. the conden
sation begins to run into the
evaporation pan, at the rear of the
appiiance. To prevent the
evaporation pan from overfiowing in
this case, mop up the condensation
with a sponge.
The evaporator is defrosted when
the water stops running into the
evaporation pan. Ciean the interior.
Switch the appiiance back on again.
Customer service
Your iocai customer service can be found
in the teiephone directory or in the
customer-service index. Piease provide
customer service with the appiiance
product number (E-Nr.) and production
number (FD).
These specifications can be found on the
rating piate. Fig. D
To prevent unnecessary call-outs, please
assist customer service by quoting the
product and production numbers.
This will save you additional costs.