Mobile home - additional installation requirements, It is your responsibility, Awarning – Kenmore ELITE HE4 110.C8586 Manuel d'utilisation
Page 7
Attention! Le texte de ce document a été détectée automatiquement. Pour consulter le document original, vous pouvez utiliser le mode "Original".

Closet installation - Dryer only
(7.6 cm)
J7.6 cm)
AWARNING
■
'ii
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
A. Side view - closet or confined area
B. Closet door with vents
Recessed or closet installation - Dryer on pedestal
71
B
A. Recessed area
B. Side view - closet or confined area
Mobile home - additional installation requirements
This dryer is suitable for mobile home installations.
The installation must conform to the Canadian Manufactured
Home Standard, CAN/CSA Z240 MH.
Mobile home installations require:
■ Metal exhaust system hardware which is available for
purchase from your local Sears store or Sears Service Center.
■ Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
It is your responsibility
■ To contact a qualified electrical installer.
■ To be sure that the electrical connection is adequate and in
conformance with the Canadian Electrical Code, C22.1 -latest
edition and all local codes. A copy of the above codes
standard may be obtained from: Canadian Standards
Association, 178 Rexdale Blvd., Toronto, ON M9W 1R3
Canada.
■ To supply the required 4 wire, single phase, 115/230-volt,
60-Hz., AC-only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an individual
branch circuit.
■ This dryer is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft (1.52 m) in length. Be sure
wall receptacle is within reach of dryer’s final location.
4-wire receptacle 14-30R
m Do not use an extension cord.
If using a replacement power supply cord, it is recommended
that you use Power Supply Cord Replacement Part Number
3394208. For further information, please call 1-800-4-MY-HOMP